■お問い合わせ先
株式会社 ヨコモ アフターサービス部
〒305-0861 茨城県つくば市谷田部 4385-2 TEL:029-896-3888 FAX:029-896-3889
※お電話でのお問い合わせは、営業時間9時〜12時、13時〜17時(祝祭日を除く月〜金)にお願いします。
YOKOMO LTD. 4385-2 Yatabe, Tsukuba City, Ibaraki Prefecture, 305-0861.JAPAN
TEL +8129-896-3888 FAX +8129-896-3889
URL http://www.teamyokomo.com
R160R100 V2.1 202104
Mode
No.
Item
Setting value
Min
Max
Blinky Default
A.POWER
SETTING
1
PWM Frequency
2000-32000Hz Adjustable,Step:500Hz
2
32
4000
8
2
Punch
Level:1-30 Adjustable,step:1
1
30
30
30
3
Compress
0-50% Adjustable,Step:1%
0
50
0%
0
4
Throttle Feel
Level1-5 Adjustable,Step:1
1
5
1
1
5
Max Reverse Force
50%-100% Adjustable,Step:1%
30
100
30%
30
B.Brake
Setting
1
Drag Brake
OFF,0-30% Adjustable,Step:1%
0
30
0
0
2
BrakePunch
Level:1-30 Adjustable,Step:1
1
30
30
30
3
Initial Brake
(=Dragbrake,1-30%Adjustable,Step:1%)
0
30
0
0
4
Brake Frequency
1000-5000Hz Adjustable,Step:50Hz
1
50
1000
20
5
MaxBrake Force
0-100% Adjustable,Step:1%
0
100
100%
100
C:Timing Setting
1
Boost Timing Activation
RPM
AUTO
0
1
RPM
0
2
Boost Timing
0-60 Adjustable,Step:1°
0
60
0
0
3
Boost Start RPM
500-35000 RPM Adjustable,Step:500RPM
1
70
500
1
4
Boost End RPM
3000-60000 RPM Adjustable,Step:500RPM
6
120
3000
6
5
Turbo Timing
0-60 Adjustable,Step:1°
0
60
0
0
6
TurboStart
50-100% Adjustable,Step:1%
50
100
95%
95
7
TurboDelay
0-1.00sec Adjustable:Step:0.01sec
0
100
0.3
3
8
TurboUpRake
(Degree/0.05sec)
1-30°/0.5sec Adjustable:Step:1Degree
1
30
30°
30
9
TurboDownRake
(Degree/0.05sec)
1-30°/0.5sec Adjustable:Step:1Degree
1
30
30°
30
D:General Setting
1
Running Mode
Forward with Brake
Forward/Reverse
Forward/Reverse/
Brake
0
2
Forward/
Brake
0
2
Battery
LiPolymer
Li-Fe
NI-XX
0
2
LiPolymer
0
3
Cut off Voltage
LOW̲2.8v/s
Middle̲3.0v/s
High̲3.2v/s
Disabled
0
3
Middle
1
4
Esc Over Heat Protect
95°
105°
120°
Disabled
0
3
115°
2
5
Motor Over Heat Protect
95°
105°
120°
Disabled
0
3
115°
2
6
NeutralRange
5%-15% Adjustable,Step:1%
5
15
6%
6
7
BEC voltage
6V
7V
0
1
6V
0
8
Motor Action
CCW
CW
0
1
CCW
0
9
Motor LinK
Normal
A SWAP C
0
1
Normal
0
10
Remote Off
Enabled
Disabled
E:Limit Value
1
VoltageMinimum
Show the battery minimum record of voltage
2
ESCtempMaximum
Show the esc maximum record of esc temperature
3
Motor Tempreature
maximum
Show the motor maximum record of temperature
4
RPM Maximum
Show the motor maximum record of RPM
ClearLimitRecord
Enter to clear all record and standby to read the coming record
F:(Load Setting)
1
BlinkyMode
Load Blinky mode Default setup
2
StockMode
Load stock mode Default setup
3
ModifyMode
Load Modify mode Default setup
4
Custom-1
Enter and enter again to load your memery of custom 1,2 or 3
Custom-2
Custom-3
G : Save
Setting
1
Custom-1
Enter and enter again to save your current setup to custom 1,
2 or 3
2
Custom-2
3
Custom-3
H:Firmware
Update
1
Load TF File
Enter import to the SD card and select the firmware version,
enter again when find the right version of firmware to update.
2
CurrentVersion
Enter to see the current firmware version.