![YOKOGAWA VZ20X Technical Information Download Page 32](http://html2.mh-extra.com/html/yokogawa/vz20x/vz20x_technical-information_3472729032.webp)
TI 77V01B01-11EN
Oct.18, 2021-00
Data Acquisition Example 2: e-RT3 and One VZ20X Unit
Programming Language: C
VZ20X
IP address: 192.168.1.1
Modbus exclusive function code
70/71
This configuration consists of the e-RT3 and one VZ20X unit.
The sample program performs data acquisition only.
Description
Details
VZ20X connection type
1 unit
Programming language on PC
C
e-RT3 CPU
F3RP71, F3RP70
(Ubuntu image)
e-RT3
IP address: 192.168.1.128
Data Acquisition Example 2: VZ20X Settings When Using
e-RT3 with One VZ20X Unit
1. Configure the Ethernet settings.
IP address: 192.168.1.1
Subnet mask: 255.255.255.0
Default gateway: 0.0.0.0
2. Select [1 unit] for [Connection type] in
[Time synchronization].
32
Summary of Contents for VZ20X
Page 54: ...Blank Page...