IM 05P01C31-15EN  page 4/12

■  UT52A

E4-terminal area

E3-terminal area

E2-terminal area

E1-terminal area

101

102
103
104
105
106

107
108
109
110

111

501

502
503
504
505
506
507
508
509
510
511
512

407

401

408
409
410
411
412

301

302
303
304
305
306
307
308
309
310
311
312

201

202
203
204
205
206
207
208
209
210

211
212

101

-112

501

-512

401

-412

301

-312

201

-212

112

■  UT55A (Continued from page 3)

E3-Terminal Area

401-412

E4-Terminal Area

501-506

Contact input

External contact input

DI41

DI42

DI43

DI44

DI45

COM

DI41

DI42

COM

+5V

+5V

DI43

+5V

DI44

+5V

DI45

+5V

UT

UT

(Option code /X4)

Common

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

501

502

503

504

505

506

501

502

503

504

505

506

Function can be assigned to the 

terminals with no function.

DI

(Option code /X3)

Contact input

External contact input

DI31

DI32

DI33

DI34

DI35

COM

Common

DI31

DI32

COM

+5V

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

DI33

+5V

DI34

+5V

DI35

+5V

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

UT

UT

407

408

409

410

411

412

407

408

409

410

411

412

DI

Function can be assigned to the terminals with no function.

RS-485

SDB(+)

SDA(-)

RDB(+)

RDA(-)

SG

RS-485 communication

501

502

503

504

505

RS485

(Option code /C4)

RS-485

RSB(+)

RSA(-)

SG

RS-485 communication/24 V DC loop power supply

+

24 V DC loop power supply

21.6-28.0 V DC

(Max. 30 mA DC)

-

501

502

503

505

506

RS485/LPS24

(Option code /LC4)

+

24 V DC loop power supply

21.6-28.0 V DC

(Max. 30 mA DC)

-

24 V DC loop power supply

505

506

LPS24

(Option code /L4)

Aux. analog input/Contact input

(Option code /A4)

AIN4

Aux. analog input

Default: 1-5 V DC

+

-

External contact input

DI46

COM

DI46

COM

+5V

UT

UT

Common

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

503

504

503

504

505

506

Function can be assigned to the 

terminals with no function.

Aux. analog input can be used for 

feedforward input in Single-loop 

control and Single-loop position 

proportional control.

Specify within a 

range of 1-5 V DC, 

0-2 V DC,0-10 V DC

(Option code /ET3)

Ethernet communication (with gateway function)

10BASE-T/100BASE-TX

RJ45 connector

Color
Lit

Unlit

Amber
100M bps

10M bps

Green
Linked
Active
Link failure

Color
Lit
Blink
Unlit

Upper side LED (baud rate)

Lower side LED (link activity)

RS-485

RSB(+)

RSA(-)

SG

407

408

409

ETHR

RS-485

SDB(+)

SDA(-)

RDB(+)

RDA(-)

SG

RS-485 communication

(Option code /CH3)

407

408

409

410

411

RS485

Contact output

(Option code /Y3)

DO

External contact output

DO32

DO31

DO33

DO34

DO35

COM

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Common

UT

407

408

409

410

411

412

Transistor contact rating: 24 V DC, 50 mA

Contact output

External contact output

DO42

DO41

DO43

DO44

DO45

COM

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Common

UT

(Option code /Y4)

501

502

503

504

505

506

DO

Transistor contact rating: 24 V DC, 50 mA

Function can be assigned 

to the terminals with no 

function.

(Option code /W4)

Contact input / Contact output

DI/DO 

External contact output

Transistor contact rating: 24 V DC, 50 mA

DO42

DO41

COM

Common

UT

External contact input

DI41

DI42

COM

Common

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

UT

501

502

503

504

505

506

Function can be 

assigned to the 

terminals with no 

function.

DI41

DI42

COM

+5V

+5V

UT

501

502

503

RS-485 communication / Aux. analog input / Contact input

(Option code /AC4)

External contact input

DI46

COM

Common

DI46

COM

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

UT

UT

Factory default: No function

503

504

503

504

AIN4/RS485

Aux. analog input

Default: 1-5 V DC

+

-

505

506

Specify within a 

range of 1-5 V DC, 

0-2 V DC,0-10 V DC

RS-485

RSB(+)

RSA(-)

SG

501

502

503

(Option code /CC3)

CC-Link communication (with Modbus master)

Pin

1
2

Signal name

Description

DA

DB

3

DG

4

SLD

5

FG

RX/TX + signal

RX/TX - signal

TX/RX signal ground

Shield

Frame ground

RS-485

RSB(+)

RSA(-)

SG

407

408

409

CC-L

If the UT is located at the 

end of a segment for the 

CC-Link communication 

wiring, terminating 

resistors are separately 

needed.

These are to be prepared 

by users. (110 Ω: 1 pcs.)

DA

DB

110

Ω

CHK

L ERR

LED

CHK

(red)

L.RUN

(green)

Lit

Unlit

User profile error/

Address error

Normal

Normal.

Communicating successfully.

No carrier 

detected/

Connection 

timeout

Communication failure

(CRC error)

L.ERR

(red)

Normal

L RUN

1
2
3
4
5

PROFIBUS-DP communication (with Modbus master)

(Option code /PD3)

Pin

1
2

Signal name

Description

VP

RxD/TxD-P

3 RxD/TxD-N
4 DGND

5 SHIELD

+5V bus power

Data signal 

(positive data receive/transmit)
Data signal 

(negative data recive/transmit)
Signal ground
Shield ground

RS-485

RSB(+)

RSA(-)

SG

407

408

409

PROF

If the UT is located at the 

end of a segment for the 

PROFIBUS 

communication wiring, 

terminating resistors are 

separately needed.

These are to be prepared 

by users. (390 Ω: 2 pcs. 

220 Ω: 1 pc., or an active 

terminator.)

VP

RxD/TxD-P

Data 

line

Data 

line

390

Ω

220Ω

390

Ω

RxD/TxD-N

DGND

CHK
RDY
ERR

LED

CHK

(red)
RDY

(green)

Lit

Unlit

ERR

(red)

User profile error

Normal

Normal

Not connected, or 

communication failure

(flashing)

Normal. Communicating 

successfully

No power, or 

communication failure 

1
2
3
4
5

(Option code /DN3)

DeviceNet communication (with Modbus master)

RS-485

RSB(+)

RSA(-)

SG

407

408

409

DNET

If the UT is located at 

the end of a segment 

for the DeviceNet

communication wiring,

terminating resistors 

are separately needed.

These are to be  

prepared by users. 

(121 Ω: 1 pc.)

CAN_H

CAN_L

121

Ω

LED
CHK

(red)

RDY

(green/

red)

Lit/flashing

Unlit

User profile error

Normal

Pin

1
2

Signal name

Description

CAN_H

CAN_L

3

V+

4

V-

5

DRAIN

RX/TX + signal

RX/TX - signal

Shield/Drain wire

DeviceNet power supply 24V

DeviceNet power supply common

Normal. Communicating 

successfully (green, lit).

Not connected (green, flashing).
Critical link failure (red, lit).

Communication timeout (red, 

flashing)
At power-on/Communication 

faulted (green/red, flashing)

No electricity

CHK

MNS

1
2
3
4
5

(Option code /W3)

Contact input / Contact output

External contact input

DI31

DI32

COM

Common

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

Factory default: No function

UT

407

408

409

DI/DO 

Function can be assigned to 

the terminals with no function.

DI31

DI32

COM

+5V

+5V

UT

407

408

409

External contact output

Transistor contact rating: 24 V DC, 50 mA

DO32

DO31

COM

Common

UT

Factory default: No function

Factory default: No function

410

411

412

E1-Terminal Area

301-306

E2-Terminal Area

307-312

(Option code /X1)

Contact input

External contact input

DI11

DI12

DI13

DI14

DI15

COM

Common

DI11

DI12

COM

+5V

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

DI13

+5V

DI14

+5V

DI15

+5V

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

UT

UT

301

302

303

304

305

306

301

302

303

304

305

306

Function can be assigned to the terminals with no function.

DI

Contact output

External contact output (transistor)

Transistor contact rating: 24 V DC, 50 mA

DO12

DO11

DO13

DO14

DO15

COM

Common

UT

(Option code /Y1)

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

301

302

303

304

305

306

Function can be assigned to the terminal with no function.

DO

(Option code /U1)

Universal input

TC input

RTD input

Voltage (mV, V) input

+

-

+

-

Current (mA) input

+

-

4-wire

302

303

302

303

303

304

RSP

a

B

b

A 301

302

303

305

(Option code /R1)

Remote input / Contact input

External contact input

DI16

COM

Common

DI16

COM

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

UT

UT

REMOTE when DI16=ON

LOCAL when DI16=OFF

303

304

303

304

RSP

Remote input

Default: 1-5 V DC

+

-

305

306

Specify within a 

range of 1-5 V DC, 

0-2 V DC,0-10 V DC

Contact output

External contact output

Transistor contact rating: 24 V DC, 50 mA

DO22

DO21

DO23

DO24

DO25

COM

Alarm 4 (PV low limit)

Common

UT

(Option code /Y2)

307

308

309

310

311

312

Function can be assigned 

to the terminals with no 

function.

DO

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

(Option code /W1)

External contact output

Transistor contact rating: 24 V DC, 50 mA

DO12

DO11

COM

Common

UT

Contact input / Contact output

External contact input

DI11

DI12

COM

Common

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

UT

301

302

303

304

305

306

DI/DO 

Function can be assigned to the terminals with no function.

DI11

DI12

COM

+5V

+5V

UT

301

302

303

(Option code /X2)

Contact input

External contact input

DI21

DI22

DI23

DI24

DI25

COM

Common

DI21

DI22

COM

+5V

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

DI23

+5V

DI24

+5V

DI25

+5V

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

UT

UT

307

308

309

310

311

312

307

308

309

310

311

312

Function can be assigned 

to the terminals with no 

function.

DI

(Option code /W2)

External contact output

Transistor contact rating: 24 V DC, 50 mA

DO22

DO21

COM

Common

UT

Contact input / Contact output

Factory default: No function

Factory default: No function

External contact input

DI21

DI22

COM

Common

DI21

DI22

COM

+5V

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

Factory default: No function

UT

UT

307

308

309

307

308

309

310

311

312

DI/DO 

Function can be 

assigned to the 

terminals with no 

function.

(Option code /A2)

Aux. analog input

Default: 1-5 V DC

+

-

Aux. analog input / Contact input

External contact input

DI26

COM

Common

DI26

COM

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

UT

UT

309

310

309

310

311

312

Aux. analog input can 

be used for feedforward 

input in Single-loop 

control and Single-loop 

position proportional 

control.

Function can be assigned to the terminals with no function.

AIN2

Specify within a 

range of 1-5 V DC, 

0-2 V DC,0-10 V DC

(Suffix code: Output 1; -P)

(Suffix code: Output 1 and Output 2;  -UU, -UR, 

-RU or -RR.

Terminal 102 has no function in -AU and -AR.)

(Option code /HA)

PV input

TC input

RTD input

Voltage (mV, V) input

A

+

-

+

-

Current (mA) input

+

-

B

b

(Equipped

 as standard)

(Equipped

 as standard)

Control output

Contact output

External contact output (relay)

AL3

AL2

AL1

Relay contact rating: 240 V AC, 1 A

 

      30 V DC, 1 A (resistance load)

Alarm-3 output

(PV high limit)

Alarm-2 output

(PV low limit)

Alarm-1 output

(PV high limit)

Common

Common

Common

UT

Heater break alarm

Heater current detection input

CT1

CT2

COM

111

301
302
303
304
305
306

307
308
309
310
311
312

201
202
203
204
205
206
207
208

209
210

101
102
103
104
105
106

107
108
109
110

211

212

Heating/cooling control output

Heating/cooling relay contact output

NO

Heating

-side

Cooling

-side

NO

COM

Contact rating:  240 V AC, 3 A

 

        30 V DC, 3 A (resistance load)

(24 V AC/DC power supply: Option code /DC)

Position proportional control output

Resistance: 100 

Ω

 to 2.5 k

Ω

Feedback input

100%

0%

Relay contact output

HIGH

(direct)

LOW

(reverse)

COM

Contact rating: 240 V AC, 3 A

    

    30 V DC, 3 A

 

   (resistance load)

+

-

Feedback input

Current (mA)

input

When feedback input is current

E1-terminal area

101

-112

301

-312

201

-212

Relay contact output

NC

NO

COM

Contact rating: 250 V AC, 3 A

 

       30 V DC, 3 A (resistance load)

101

102

103

104

105

106

107

108

109

101

102

103

310

311

312

310

311

312

202

203

201

202

203

202

203

203

204

310

311

312

101

102

103

PV

Retransmission output

4-20 mA DC or

0-20 mA DC

15 V DC loop power supply

14.5-18.0 V DC

(Max. 21 mA DC)

+

-

+

-

Default: 4-20 mA DC

Default: PV retransmission

Load resistance 600 

Ω

 or less

Retransmission output

(Option code /RT)

205

206

205

206

Can be used for 15 V DC loop 

power supply when not used for 

retransmission output.

RET

(Equipped as standard)

Contact input

Contact rating: 12 V DC, 10 mA or more

External contact input

DI3

DI2

DI1

COM

AUTO when DI1=ON

MAN when DI1=OFF

STOP when DI2=ON

RUN when DI2=OFF

Common

DI3

DI2

DI1

COM

+5V

+5V

+5V

No-voltage

contact

Transistor contact

Factory default: No function

UT

UT

209

210

211

212

209

210

211

212

Function can be assigned to the terminals with no function.

DI

HBA

VALV

ALM

OUT

OUT

Current/voltage pulse output

0-20 mA DC,

4-20 mA DC,

Voltage pulse (12  V)

-

Retransmission output

+

-

Default: 4-20 mA DC

Default: Undefined

0-20 mA DC,

4-20 mA DC

15 V DC loop power supply

14.5-18.0 V DC

(Max. 21 mA DC)

+

-

311

312

+ 311

312

311

312

OUT2

Factory default: 

PV input type is 

undefined.

External contact output (transistor)

Transistor contact rating: 24 V DC, 50 mA

 

      

Heater break alarm-1

output

Heater break alarm-2

output

Common

HAL1

HAL2

COM

UT

307

308

309

Current/voltage pulse output

0-20 mA DC,

4-20 mA DC,

Voltage pulse (12 V)

+

-

Retransmission output

+

-

Default: 4-20 mA DC

Default: Undefined

0-20 mA DC,

4-20 mA DC

Control output

(Suffix code: Output 1; -A or -U)

15 V DC loop power supply

14.5-18.0 V DC

(Max. 21 mA DC)

+

-

207

208

207

208

207

208

Can be used for retransmission output or 15 V DC loop power suppy when 

current/voltage pulse output is not used for control output.

Current output range can be changed.

In Position proportional type, can be used for retransmission output or 15 V DC 

loop power supply.

OUT

OUT2

112

Power supply

24 V AC/DC power supply

-

+

100-240 V AC power supply

Allowable range: 

       100-240 V AC (+10%/-15%)

       (free voltage)

       50/60 Hz shared

N

L

110

111

110

111

112

112

N

L

(Suffix code: Output 1; -T)

101

102

Triac output

103

NO

COM

Contact rating: 75 - 250 V AC

Allowable load current:  0.8 A

Triac

(Suffix code: Output 1; -R or -U, 

 

and Output 2; N or A)

(Suffix code: Output 2; U or A)

Wiring direction

E1-Terminal Area

301-306

+

24 V DC loop power supply

21.6-28.0 V DC

(Max. 30 mA DC)

-

24 V DC loop power supply

(Option code /L1)

305

306

LPS24

Universal input

(Option code /U1)

TC input

RTD input

Voltage (mV, V) input

+

-

+

-

Current (mA) input

+

-

302

303

303

304

302

303

RSP

4-wire

a

B

b

A 301

302

303

305

(Option code /RCH1)

RS-485

RSB(+)

RSA(-)

SG

RS-485 communication / Remote input / Contact input

Remote input

Default: 1-5 V DC

+

-

External contact input

DI16

COM

Common

DI16

COM

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10m A or more

UT

UT

REMOTE when DI16=ON

LOCAL when DI16=OFF

301

302

303

303

304

303

304

305

306

RSP/RS485

Specify within a 

range of 1-5 V DC, 

0-2 V DC,0-10 V DC

Remote input/ Contact input

(Option code /R1)

Remote input

Default: 1-5 V DC

+

-

External contact input

DI16

COM

Common

DI16

COM

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10m A or more

UT

UT

REMOTE when DI16=ON

LOCAL when DI16=OFF

303

304

303

304

305

306

RSP

Specify within a 

range of 1-5 V DC, 

0-2 V DC,0-10 V DC

(Option code /W1)

External contact output

Transistor contact rating: 24 V DC, 50 mA

DO12

DO11

COM

Common

UT

Contact input / Contact output

External contact input

DI11

DI12

COM

Common

DI11

DI12

COM

+5V

+5V

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

UT

UT

301

302

303

301

302

303

304

305

306

DI/DO 

Function can be 

assigned to the 

terminals with no 

function.

RS-485

RSB(+)

RSA(-)

SG

RS-485 communication/24 V DC loop power supply

+

24 V DC loop power supply

21.6-28.0 V DC

(Max. 30 mA DC)

-

301

302

303

305

306

RS485/LPS24

(Option code /LCH1)

RS-485

SDB(+)

SDA(-)

RDB(+)

RDA(-)

SG

RS-485 communication

301

302

303

304

305

RS485

(Option code /CH1)

Contact input

External contact input

DI11

DI12

DI13

DI14

DI15

COM

DI11

DI12

COM

+5V

+5V

DI13

+5V

DI14

+5V

DI15

+5V

UT

UT

(Option code /X1)

Common

No-voltage contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

301

302

303

304

305

306

301

302

303

304

305

306

Function can be assigned to the 

terminals with no function.

DI

Contact output

External contact output

DO12

DO11

DO13

DO14

DO15

COM

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Common

UT

(Option code /Y1)

301

302

303

304

305

306

DO

Transistor contact rating: 24 V DC, 50 mA

Function can be assigned to the 

terminals with no function.

Summary of Contents for UTAdvanced UT52A

Page 1: ...ish are available for the guide display 2 For heating cooling output both Output 1 and Output 2 should be specified Not available when Output 2 is N For position proportional output specify P for Outp...

Page 2: ...o 5 000 V 0 1 of instrument range 1 digit DC voltage 0 000 to 2 000 V 0 2 of instrument range 1 digit 0 00 to 10 00 V 0 1 of instrument range 1 digit DC voltage for high input impedance 0 000 to 1 250...

Page 3: ...208 Can be used for retransmission output or 15 V DC loop power supply when current voltage pulse output is not used for control output Current output range can be changed In Position proportional ty...

Page 4: ...nal contact output Transistor contact rating 24 V DC 50 mA DO22 DO21 DO23 DO24 DO25 COM Alarm 4 PV low limit Common UT Option code Y2 307 308 309 310 311 312 Function can be assigned to the terminals...

Page 5: ...ting Software is on the top of the unit 2 Setup Procedure The following flowchart shows the setup procedure for UT55A and UT52A Install and wire a controller Monitoring and control of regular operatio...

Page 6: ...type is displayed Press the SET ENTER key 5 6 Energized De energized Latch action Stand by action The alarm 1 type setpoint 02 PV low limit is registered After the setup is completed press the DISPLAY...

Page 7: ...int has been registered This starts auto tuning The limiter can be set to the output during auto tuning For details see User s Manual IM 05P01C31 01EN The MAN lamp goes off which means that the auto t...

Page 8: ...function E1 to E4 terminal areas Faulty Contact us for repair Normal indication Normal indication Rightmost decimal point on PV display blinks Setup parameter PA ER Calibration value error Initialized...

Page 9: ...4 SP low limit 05 Deviation high limit 06 Deviation low limit 07 Deviation high and low limits 08 Deviation within high and low limits 09 Target SP high limit 10 Target SP low limit 11 Target SP devia...

Page 10: ...king state allows you to make changes setting mode Use the Up Down Left Right arrow keys to change the setpoint Press the SET ENTER key to register the setting Note that there are some parameters whic...

Page 11: ...ge O1RS Retransmission output type of OUT current output Same as RTS OFF STD O1RH Maximum value of retransmission output scale of OUT current output When O1RS PV1 SP1 PV2 SP2 TSP1 TSP2 PV RSP AIN2 or...

Page 12: ...ion Set an I relay number For the items other than below see Communication User s Manual Ex Set the number 4353 for AL1 S to use the alarm 1 Set OFF to disable the function No function OFF Alarm 1 435...