background image

6

IM 77C01U01-01E

1st Edition : Dec. 26, 2000-00

Outline of Each Section

Panel switch

Status indicator
(LED-RED)

Data display
(7seg LED)

1

2

4

5

6

7

8

3

9

10

11

12

14

13

1

kWh (Integration)
Light on when data on Display Section is inte-
grated power [kWh].

2

Wh (Optional Integration)
Light on when data on Display Section is optional
integrated power [Wh].

3

W (Power)
Light on when data on Display Section is power
momentary value [W].

4

V (Voltage)
Light on when data on Display Section is voltage
momentary value [V].

5

A (Current)
Light on when data on Display Section is current
momentary value [A].

6

cos 

φ

Light on when data on Display Section is power
factor momentary value [cos 

φ

].

7

X  10

3

Light on when data value on Display Section is kilo
unit. And light on when integrated power value is
mega unit.

8

X  10

6

Light on when data value on Display Section is
mega unit.

9

COMM
Light on during communication (RS-485 commu-
nication) is made.

10 Display Section

Display measured value data, preset parameter
symbol, set value data, adjustment parameter
symbol, adjustment data and the like.

(1) Measurement items: integrated power, op-

tional integrated power, power momentary
value voltage momentary value, current mo-
mentary value, power factor momentary value

(2) Setting items: RS-485 station number, data

transmission rate, lower limit of input range,
upper limit of input range, PT ratio, CT ratio, in-
tegrating low cut power, integrating pulse unit
(fixed point part, exponent), integrating pulse
ON pulse duration

(3) Adjustment items: power momentary value in-

put zero, power momentary value input
span,voltage momentary value input zero, volt-
age momentary input span, current momen-
tary value input zero, current momentary value
input span, power momentary value input
zero, power momentary value input span

11

SET/ENT

 SET/ENT Switch

This switch is used for changing over displays of
screens and items. It is also used for registration of
set values and adjusted values.  Pressing the
switch for 3 seconds or more changes over the dis-
plays for measured value, parameter setting, or
input/output adjusting.

12

 Range Switch

This switch is used for changing over display of
phases. It is also used for shifting digit position and
decimal position of set values on parameter setting
display.

13

 Figure UP switch

This switch is used for the followings:

1. Increase the set value on parameter setting

display.

2. Display the maximum value of voltage or cur-

rent.

3. Increase the adjusted value at input/output ad-

justment. I

14

 Figure DOWN switch

This switch is used for the followings:

1. Parameter decrement at parameter setting.

2.

Display the minimum value of voltage or current

3.

Decrease the adjusted value at input/output adjust-
ment

Summary of Contents for Powercert UZ005

Page 1: ...User s Manual IM 77C01U01 01E Model UZ005 Power Monitor IM 77C01U01 01E 1st Edition ...

Page 2: ...Blank Page ...

Page 3: ...to connect the grounding 3 Turn off the product before installation and wiring 4 Use the power supply within specifications 5 Observe the following instructions for correct installation Recommended panel thickness is 1 to 10mm Install the product horizontally Install the product using attached fixture from the backside of the product Turn the screw only up to 180 after the screw touches the mounti...

Page 4: ...t 1 2 110V can also be used at 120V input Note 3 Rated input 5 6 440V is the specs only for 1 phase 2 wire system and 3 phase 3 wire system Note 4 Rated input A to F is the specs for only 3 phase 4 wire system Rated input voltage indicates phase voltage A B 64V C D 127V E F 227V indicate 110V 3 220V 3 480V 3 respectively In case of 440V 3 input it can be used at E F 227V of rated input Note 5 Spec...

Page 5: ...c 26 2000 00 External Dimensions and Panel Cutout Dimensions External Dimensions 96 90 8 90 8 96 11 100 30 Fixturs 91 8 112 Fixturs Panel thickness 1 to10 mm Terminal Cover Panel Cut Dimension Min 130 Min 117 92 0 8 0 92 0 8 0 Unit mm ...

Page 6: ... to overtighten them Large bracket top mounting hardware Terminal board Small bracket bottom mounting hardware Panel Insert a screwdriver into the brackets to tighten the screws Direction to insert the product Insert the product into the opening at the front of the panel Terminal Arrangement 40 screw M3 5 1 phase 2 wire system Terminat No 1 2 51 52 3 4 53 54 5 6 55 56 9 59 10 60 31 32 33 34 35 36 ...

Page 7: ...R 7 57 8 58 2 52 4 54 P1 P3 P2 9 10 1 51 3 53 5 55 6 56 PT CT CT CT K L K L K L 1S 1L 2S 2L 3S 3L P0 60 59 N 3 11 12 13 14 15 18 40 20 31 32 33 34 35 36 16 37 17 38 39 19 Power Side Load Side L N Power Supply Communication Short Terminating Voltage or Contact A B C Shild Receiver Device 2 1 T S R 3 phase 3 wire system 3 phase 4 wire system CAUTION The following caution for safety should be taken f...

Page 8: ...ms RS 485 station number data transmission rate lower limit of input range upper limit of input range PT ratio CT ratio in tegrating low cut power integrating pulse unit fixed point part exponent integrating pulse ON pulse duration 3 Adjustment items power momentary value in put zero power momentary value input span voltage momentary value input zero volt age momentary input span current momen tar...

Page 9: ...rated pulse unit characteristic setting 4 Integrated pulse ON width setting 4 RS 485 communication protocol setting 4 RS 485 station number setting 4 RS 485 data baud rate setting 4 LON communication node number setting 4 LON communication integrated power data transmission period setting minute 4 LON communication integrated power data transmission period setting second 4 LON communication power ...

Page 10: ...nge numeral column at pressing key 5 Change numeral column at pressing and key 6 Fixing numeral value at pressing key 7 Light on and off of setting value 8 If the setting is complete correctly press key If required correcting press any of key key and key then repeat from step 1 7 Example of Communication Connection RS232 C Converter RS232 C Cable Short circuit terminating 33 34 35 33 34 35 36 37 A...

Page 11: ...0000 MW and the value calculated by the formula below is within above input measuring range list Input range W Primary side input power W PT ratio x CT ratio Rated power factor LEAD 0 5 to 1 to LAG 0 5 Optional integrated control signal Input point 1 point Input signal contact or voltage Contact signal ON signal OFF signal below 200 over 100k Voltage signal 1V DC below 200 4 5 to 25V DC ON signal ...

Page 12: ...9MW 10MW over Display decimal point 0 to 99999kWh 0 00 to 999 99MWh kWh 103 0 0 to 9999 9MWh kWh 103 0 to 99999kWh kWh 103 Inregrated power data is reset to zero when the data exceed maximunm display value Setting range Rated power 100W 200W 300W 400W 500W 600W 800W 1000W 1500W 2000W 3000W 4000W 5 556 10 6 to 1 000 10 1kWh pulse 6 667 10 6 to 1 000 10 1kWh pulse 1 000 10 5 to 1 000 10 1kWh pulse 1...

Page 13: ...pair cable Optional integrated power 䊐䊐䊐䊐䊐 Wh w o symbol integer 5 digits Instantanous power 䊐䊐䊐 䊐 W to 䊐䊐䊐䊐 MW w symbol floating decimal point 4 digits minimum resolution 0 1W Voltage r m s value 䊐䊐䊐 䊐 V to 䊐䊐䊐䊐 kV w o symbol floating decimal point 4 digits minimum resolution 0 1V Current r m s value 䊐 䊐䊐䊐 A to 䊐 䊐䊐䊐 kA w o symbol floating decimal point 4 digits minimum resolution 0 001A Voltage ...

Page 14: ...200 Data format Start bit 1 bit Data bit 8 bits Parity None Stop bit 1 bit Error detect SUM CHECK simply adding 2 bytes Xon Xoff Control None Terminating character designation Yes CR Station number setting Can be set through parameter setting screen Setting range 1 to 31 Communication error disposal If data received is other than command reading is ignored and no disposal be made noise or erroneou...