v

IM 701988-01E

 

•  Do not use the probe near flammable gases.
  To avoid injury and fire, do not use the probe near flammable or 

explosive gasses or vapors.  

•  Avoid exposed circuits.  
  To prevent injury, when the power is ON, do not touch any exposed 

contact points or components.

 CAUTION

•  Be sure to use the accessory probe lead set when connecting to the 

circuit under test. 

•  The instrument’s GND lead is of the same electric potential as the 

grounding of the connected oscilloscope. 

•  This is a precision-manufactured instrument. Damage can occur as a 

result of sudden changes in ambient temperature or physical shocks. 
Handle with care.  

•  To prevent trouble such as breakages or contact failures, please note 

the following when handling the cable connected to the instrument. 
•  Do not apply force to the connectors. 
•  Never bend the cable to a radius of less than 60 mm. 
•  Never apply force to a small part of the cable, nor deform the cable. 

•  Never twist or pull the probe leads or GND lead any more than 

necessary. The wires inside the leads can break, causing malfunction. 

•  Avoid vibration, shock, and static electricity when transporting or 

handling the instrument. Especially take care not to shock the instrument 
such as by dropping it. 

•  Avoid storing or using the probe in direct sunlight, or areas that have 

high heat, humidity, or condensation. The probe can become deformed 
or its insulation can deteriorate, resulting in the probe failing to meet its 
specifications.  

•  Before use, inspect and check the operation of the probe to confirm that 

no problems have been caused by harsh storage or transport conditions. 
If problems are found, please contact your nearest YOKOGAWA dealer 
or representative. 

•  This instrument is not drip- or dust-proof. Do not use in areas where it 

may come into contact with water or a large amount of dust. 

Summary of Contents for PBL100

Page 1: ...User s Manual Model 701988 PBL100 Logic Probe IM 701988 01E 6th Edition...

Page 2: ...provided on the following sheet Document No Description PIM 113 01Z2 List of worldwide contacts Notes The contents of this manual are subject to change without prior notice as a result of continuing...

Page 3: ...be taken to prevent such occurrences CAUTION Calls attention to actions or conditions that could cause light injury to the user or damage to the instrument or user s data and precautions that can be...

Page 4: ...6 7 8 9 1 2 3 4 5 6 7 PBL100 Logic Probe Name Qty Part Number 1 Logic probe 1 2 Probe lead set 1 B8099BS 3 Cable 1 5 m 1 B9852VN Standard Accessories Name Qty Part Number 4 Microclips black set of 2 1...

Page 5: ...sation et d entretien Ce symbole a t appos aux endroits dangereux de l instrument pour lesquels des consignes sp ciales d utilisation ou de manipulation ont t mises Le m me symbole appara t l endroit...

Page 6: ...er bend the cable to a radius of less than 60 mm Never apply force to a small part of the cable nor deform the cable Never twist or pull the probe leads or GND lead any more than necessary The wires i...

Page 7: ...z inflammables Pour viter toute blessure et incendie n utilisez pas la sonde proximit de gaz ou de vapeurs inflammables ou explosifs vitez les circuits expos s Pour viter toute blessure lorsque l appa...

Page 8: ...iles Si des probl mes sont d tect s veuillez contacter votre revendeur ou repr sentant YOKOGAWA le plus proche Cet instrument n est pas tanche aux gouttes d eau ou la poussi re Ne l utilisez pas dans...

Page 9: ...stic household waste When disposing of products in the EEA or UK contact your local Yokogawa office in the EEA or UK respectively EEA European Economic Area Authorized Representative in the EEA Yokoga...

Page 10: ...i Checking the Contents of the Package iii Safety Precautions iv Regulations and Sales in Various Countries and Regions viii Overview 1 Names and Functions of Parts 2 Usage Precautions 3 Operating Pr...

Page 11: ...re compatible with this instrument please contact your nearest YOKOGAWA representative Features High input impedance 1 M 10 pF each input terminal to ground Wide input voltage range 40 V Supports 2 54...

Page 12: ...ion to the circuit under test consisting of 8 probe leads and 2 GND leads Probe Leads The points of connection to the circuit under test Can be directly connected to 2 54 mm pitch pin headers GND Lead...

Page 13: ...le jeu de fils de la sonde est retir et remplac par un autre destin un autre mod le d instrument Lors du nettoyage utilisez un chiffon doux et veillez ne pas endommager la sonde De plus n immergez jam...

Page 14: ...4 IM 701988 01E Usage Example Probe Lead Set 2 54 mm Pitch Pin Header Probe Lead Set Microclips...

Page 15: ...Input voltage range 40 V Min input voltage2 500 mVp p Hysteresis voltage 100 mV typical 3 Input impedance 1 M 10 pF typical 3 Maximum toggle frequency2 100 MHz or more Min pulse width2 5 ns 1 See dera...

Page 16: ...Group1 EMC standards of Australia and New Zealand EN55011 Class A Group1 Korea Electromagnetic Conformity Standard This is a Class A product Operation of this product in a residential area may cause...

Page 17: ...ecome damaged Please use the following components Name Part Number Probe lead set B8099BS Cable 1 5 m B9852VN Replacing the Probe Lead Set Remove the probe lead set from the logic probe then align the...

Reviews: