IM 12B07K02-01E

  

<INTRODUCTION>

iii

  After-sales Warranty

n

  Do not modify the product.

n

  During the warranty period, for repair under warranty consult the local sales representative 

or service office. Yokogawa will replace or repair any damaged parts. Before consulting for 

repair under warranty, provide us with the model name and serial number and a description 

of the problem. Any diagrams or data explaining the problem would also be appreciated.

•  If we replace the product with a new one, we won’t provide you with a repair report.
•  Yokogawa warrants the product for the period stated in the pre-purchase quotation 

Yokogawa shall conduct defined warranty service based on its standard. When the 

customer site is located outside of the service area, a fee for dispatching the maintenance 

engineer will be charged to the customer.

•  Returned goods that have been in contact with process fluids must be decontaminated 

and disinfected prior to shipment. Goods should carry a certificate to this effect, for the 

health and safety of our employees. Material Safety Data sheets must be included for all 

components of the process to which the sensor have been exposed.

n

  In the following cases, customer will be charged repair fee regardless of warranty period.

•  Failure of components which are out of scope of warranty stated in instruction manual.
•  Failure caused by usage of software, hardware or auxiliary equipment, which Yokogawa 

Electric did not supply.

•  Failure due to improper or insufficient maintenance by user.
•  Failure due to modification, misuse or outside-of-specifications operation which Yokogawa 

does not authorize.

•  Failure due to power supply (voltage, frequency) being outside specifications or abnormal.

•  Failure caused by any usage out of scope of recommended usage.

•  Any damage from fire, earthquake, storms and floods, lightning, disturbances, riots, warfare, 

radiation and other natural changes.

n

  Yokogawa does not warrant conformance with the specific application at the user site. 

Yokogawa will not bear direct/indirect responsibility for damage due to a specific application.

Yokogawa Electric will not bear responsibility when the user configures the product into 

systems or resells the product.

Maintenance service and supplying repair parts will be covered for five years after the 

production ends. For repair for this product, please contact the nearest sales office 

described in this instruction manual.

4th Edition : Nov.20,2018-00

Summary of Contents for FU20

Page 1: ...User s Manual Model FU20 pH ORP Sensor IM 12B07K02 01E IM 12B07K02 01E 4th Edition...

Page 2: ...g outer box and then immediately notify the carrier and the relevant Yokogawa sales office Make sure the Model Code on the sensor is the same as on the packing list For details of the Model Code refer...

Page 3: ...fore using the product The purpose of these user s manuals is not to warrant that the product is well suited to any particular purpose but rather to describe the functional details of the product No p...

Page 4: ...to which the sensor have been exposed n In the following cases customer will be charged repair fee regardless of warranty period Failure of components which are out of scope of warranty stated in inst...

Page 5: ...Blank Page...

Page 6: ...r the safe use of this equipment ii After sales Warranty iii 1 Specification 1 1 1 1 Standard Specifications 1 1 1 2 Model and Suffix codes 1 1 1 3 External Dimensions 1 2 2 Installation and Wiring 2...

Page 7: ...Blank Page...

Page 8: ...verter Applicable holder Special order for PH8HG HH350G with optional adapter cannot be used with HH350G JT Note The temperature sensor included in the FU20 is intended to provide indication and cell...

Page 9: ...13 14 11 12 150 19 6 22 5 6 5 19 6 25 9 PG7 Cable length 5 m or 10 m Standard type FU20 T1 NPT Sensor body PPS resin Note Can be fixed to 3 4NPT female screw 3 4 inch tapered thread Note 3 4 inch tap...

Page 10: ...an immersion assembly For best results the FU20 should be mounted with the process coming towards the sensor and positioned at least 15 above the horizontal plane to eliminate air bubbles in the glass...

Page 11: ...REFERENCE SOLUTION GROUND GLASS Measure GE SHIELD 11 12 13 14 15 16 Wire Marking Figure 2 3 Sensor Wiring for pH measurement For ORP measurement PG7 FLXA202 FLXA21 FLXA402 PH450G 2 REFERENCE SOLUTION...

Page 12: ...tion clean off remaining stains by rinsing with water Stains due to Oily Materials Wash off stains by submerging in a neutral detergent solution in a beaker etc for from several tens of minutes to sev...

Page 13: ...Blank Page...

Page 14: ...code of NAG deleted for Model and suffix codes FU20 P 1 2 Some revision of external dimensions P 2 1 Some revision of Installation and In line Installation added screw in torque changed P 2 2 Some re...

Page 15: ...Blank Page...