YOKOGAWA FD20 Instruction Manual Download Page 5

IM12B06K02-01E-E

The model FD20 immersion fittings are used 

to submerge sensor tips so that the pH and/

or ORP (redox) potential of liquids in open 

vessels, tanks, drains etc. can be measured.

The fittings are available for mounting of 

either:  - one electrode 

- three electrodes 

-  four electrodes or alternatively three 

electrodes and a cleaning system.

1.1 Features

•   Designed for either pH or ORP measure-

ments in tanks, open vessels and drains.

•  “Hoisting cable” for easy maintenance.

•  Pre-selected immersion length.

•   Wide choice of construction materials.

•    Flange  mounting.

•   High degree of standardisation reduces 

spare holding requirements.

•  Liquid earth pin for stable measurements.

•   Chemical or brush cleaning systems as 

an option. 

1.2 Unpacking and Checking

Upon delivery, unpack the fitting carefully 

and inspect it to ensure that it is not 

damaged during shipment. If damage is 

found, retain the original packing material 

and immediately notify the carrier and the 

relevant local Yokogawa Sales Office. 

Make sure the Model Code and Serial 

Number on the sensor are the same as on 

the packing list. Also check if option(s) that 

were ordered, are included and correct.

1.3 Warranty and Service

Yokogawa products are guaranteed free 

from defects in workmanship and materials 

under normal use and service for a period 

of (typically) 12 months from the date of 

shipment from the manufacturer. Individual 

Sales organizations can deviate from the 

typical warranty period, and the conditions 

of sale relating to the original purchase order 

should be consulted. Damage caused by 

wear and tear, inadequate maintenance, 

corrosion, or by the effects of chemical 

processes is excluded from this warranty 

coverage. In the event of a warranty claim, 

the defective goods should be sent (freight 

paid) to the Service Department of the 

relevant Yokogawa Sales office for repair or 

replacement (at Yokogawa’s discretion). 

The following information must be included in 

the letter accompanying the returned goods:

•  Model Code and Serial Number.

•  Original Purchase Order and Date.

•  Length of time in service and description of 

the process.

•  Description of the fault and circumstances 

of the failure.

•  Process/environmental conditions that may 

be related to the failure of the sensor.

•  Statement as to whether warranty or non-

warranty service is requested.

•  Complete shipping and billing instructions 

for return of material, plus the name and 

phone number of a contact person that 

can be reached for further information.

•  Clean Statement 

Returned goods that have been in 

contact with process fluids must be 

decontaminated and disinfected prior to 

shipment. Goods should carry a certificate 

to this effect, for the health and safety of 

our employees. Material Safety Data sheets 

must be included for all components of the 

process to which the fitting(options) have 

been exposed.

1. Introduction

IM12B06K02-01E-E_ed09.indd   5

07/03/16   09:51

Summary of Contents for FD20

Page 1: ...IM 12B06K02 01E E 9th edition Instruction Manual Model FD20 Immersion Fittings pH ORP YOKOGAWA IM12B06K02 01E E_ed09 indd 1 07 03 16 09 51...

Page 2: ...IM 12B06K02 01E E 2 IM12B06K02 01E E_ed09 indd 2 07 03 16 09 51...

Page 3: ...pe mounting 12 3 2 2 Flange mounting fitting 12 3 3 Cables and sensor mounting 13 3 3 1 1 Hole fitting 13 3 3 2 3 Hole and 4 hole fitting 15 4 Mounting of Accessoires 16 4 1 Mounting kit option B FP20...

Page 4: ...IM 12B06K02 01E E 4 IM12B06K02 01E E_ed09 indd 4 07 03 16 09 51...

Page 5: ...shipment from the manufacturer Individual Sales organizations can deviate from the typical warranty period and the conditions of sale relating to the original purchase order should be consulted Damage...

Page 6: ...tion Year code Year Year code Year Year code 2014 P 2026 3 2015 R 2027 4 2016 S 2028 5 2017 T 2029 6 2018 U 2030 7 2019 V 2031 8 2020 W 2032 9 2021 X 2033 A 2022 Y 2034 B 2023 Z 2035 C 2024 1 2036 D 2...

Page 7: ...s are not included The noted weights are at an immersion length of 1 m Mounting by means of the hoisting eye or flange mounting 2 2 Functional specifications Temperature min 10 C max depending on mate...

Page 8: ...1 electrode mounting holes Immersion Between 5 and 20 in dm length 2 example 06 0 6 m Flange 3 NF No flange Working F1 Flange DN32 for 1 hole fitting pressure F2 Flange DN80 for 3 hole fitting PP not...

Page 9: ...12B06K02 01E E 9 2 4 External dimensions 90 75 ISO 228 2 G 1 2 2x k D 125 b dg dg D k b 30 25 40 L ISO 228 2 G1 2 1 hole PVC 3 hole PP and PVDF Flange Flange IM12B06K02 01E E_ed09 indd 9 07 03 16 09 5...

Page 10: ...k D b 35 dg L 35 L 130 110 M8 ISO 228 2 G1 2 3x L 76 80 ISO 228 2 G 1 2 2x 80 10 3 hole SS b 188 k D L dg 4 hole PP and PVDF IM 12B06K02 01E E Flange Flange IM12B06K02 01E E_ed09 indd 10 07 03 16 09 5...

Page 11: ...20dm 200 160 18 20 FD20 P37 S2 5 20dm 190 152 4 20 18 FD20 F37 S3 5 20dm 190 152 4 20 18 FD20 S37 NF 5 20dm FD20 S37 F4 5 20dm 200 160 18 20 FD20 S37 S4 5 20dm 228 6 190 5 19 23 8 FD20 P47 NF 5 20dm F...

Page 12: ...ts and accessories were supplied by Yokogawa Ensure that there is enough spare around to withdraw the fitting for calibration and maintenance 3 2 1 Hoisting eye type mounting On top of each fitting is...

Page 13: ...s shown in figure 3 3 Fig 3 2 Electrode cables Model code Suffix code Description WU20 D Electrode cable Type PC COAX LT TRIAX Length in mm 01 1 mtr 02 2 mtr 05 51 2 mtr 10 10 mtr 15 15 mtr 20 20 mtr...

Page 14: ...hole fitting O rings 11x3 Electrode cable model WU20 Attention Ensure that the cable has slack remaining in the fitting so that sensor replacement is simplified To prevent damage of the O rings the nu...

Page 15: ...w end see figure 3 4 Prepare the sensors to be used in accordance with the directions for use and mount them in the fitting as shown in fig 3 4 For stable measurements the glass and reference electrod...

Page 16: ...of the electrodes see seperate sheets Parts and accessories Order nr Description FP20 S13 Mounting kit for SR20 AC32 10x K1500HC Rubber rings for FP20 S13 10x K1500GE O rings for SR20 D AC32 electrode...

Page 17: ...ows the mounting Note The pressure on the KCI solution must always exceed the liquid pressure The refillable electrodes can be connected to a KCI reservoir via a silicone tubing see figure 4 2 The pre...

Page 18: ...of cleaning systems see figure 4 3 brush cleaning electrically or pneumatically driven chemical cleaning 4 3 1 Selection criteria Cleaning system Mechanical Chemical Applications with Brush Acid Base...

Page 19: ...tem wipes across the glass membrane of the electrode every 30 seconds Electrically or pneumatically driven versions are available Figures 4 4a and 4 4b show the mounting Control unit Parts and accesso...

Page 20: ...n the liquid to be measured The cleaning period and frequency can be adjusted on a control unit The mounting procedure is shown in figure 4 5 Parts and accessories Order nr Description K1520FJ Tubing...

Page 21: ...ng set PPS Ryton O ring silicone Connection nylon Weight approx 300 g Mounting wall mounting support with hole for screw M5 Temperature pressure ratio max 200 kPa 2 bar at 100 C Parts and accessories...

Page 22: ...S K1500FC EPDM Set O rings for 3 hole fitting SS K1500GX Set O rings for 4 hole fitting SS K1500FH viton Set O rings for 4 hole fitting SS K1500FG EPDM Set O rings for 4 hole fitting SS K1500DQ 10 m p...

Page 23: ...IM12B06K02 01E E 23 1 Hole PVC Note This fitting has no liquid earth connection 3 Hole PP and PVDF 4 Hole PP and PVDF 3 Hole SS 4 Hole SS IM12B06K02 01E E_ed09 indd 23 07 03 16 09 51...

Page 24: ...awa com eu YOKOGAWA ELECTRIC CORPORATION World Headquarters 9 32 Nakacho 2 chome Musashino shi Tokyo 180 8750 Japan www yokogawa com YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan GA 30265 USA www...

Reviews: