YOKOGAWA FD20 Instruction Manual Download Page 1

IM 12B06K02-01E-E

9th edition

Instruction

Manual

Model FD20
Immersion Fittings 

pH/ORP

YOKOGAWA

IM12B06K02-01E-E_ed09.indd   1

07/03/16   09:51

Summary of Contents for FD20

Page 1: ...IM 12B06K02 01E E 9th edition Instruction Manual Model FD20 Immersion Fittings pH ORP YOKOGAWA IM12B06K02 01E E_ed09 indd 1 07 03 16 09 51...

Page 2: ...IM 12B06K02 01E E 2 IM12B06K02 01E E_ed09 indd 2 07 03 16 09 51...

Page 3: ...pe mounting 12 3 2 2 Flange mounting fitting 12 3 3 Cables and sensor mounting 13 3 3 1 1 Hole fitting 13 3 3 2 3 Hole and 4 hole fitting 15 4 Mounting of Accessoires 16 4 1 Mounting kit option B FP20...

Page 4: ...IM 12B06K02 01E E 4 IM12B06K02 01E E_ed09 indd 4 07 03 16 09 51...

Page 5: ...shipment from the manufacturer Individual Sales organizations can deviate from the typical warranty period and the conditions of sale relating to the original purchase order should be consulted Damage...

Page 6: ...tion Year code Year Year code Year Year code 2014 P 2026 3 2015 R 2027 4 2016 S 2028 5 2017 T 2029 6 2018 U 2030 7 2019 V 2031 8 2020 W 2032 9 2021 X 2033 A 2022 Y 2034 B 2023 Z 2035 C 2024 1 2036 D 2...

Page 7: ...s are not included The noted weights are at an immersion length of 1 m Mounting by means of the hoisting eye or flange mounting 2 2 Functional specifications Temperature min 10 C max depending on mate...

Page 8: ...1 electrode mounting holes Immersion Between 5 and 20 in dm length 2 example 06 0 6 m Flange 3 NF No flange Working F1 Flange DN32 for 1 hole fitting pressure F2 Flange DN80 for 3 hole fitting PP not...

Page 9: ...12B06K02 01E E 9 2 4 External dimensions 90 75 ISO 228 2 G 1 2 2x k D 125 b dg dg D k b 30 25 40 L ISO 228 2 G1 2 1 hole PVC 3 hole PP and PVDF Flange Flange IM12B06K02 01E E_ed09 indd 9 07 03 16 09 5...

Page 10: ...k D b 35 dg L 35 L 130 110 M8 ISO 228 2 G1 2 3x L 76 80 ISO 228 2 G 1 2 2x 80 10 3 hole SS b 188 k D L dg 4 hole PP and PVDF IM 12B06K02 01E E Flange Flange IM12B06K02 01E E_ed09 indd 10 07 03 16 09 5...

Page 11: ...20dm 200 160 18 20 FD20 P37 S2 5 20dm 190 152 4 20 18 FD20 F37 S3 5 20dm 190 152 4 20 18 FD20 S37 NF 5 20dm FD20 S37 F4 5 20dm 200 160 18 20 FD20 S37 S4 5 20dm 228 6 190 5 19 23 8 FD20 P47 NF 5 20dm F...

Page 12: ...ts and accessories were supplied by Yokogawa Ensure that there is enough spare around to withdraw the fitting for calibration and maintenance 3 2 1 Hoisting eye type mounting On top of each fitting is...

Page 13: ...s shown in figure 3 3 Fig 3 2 Electrode cables Model code Suffix code Description WU20 D Electrode cable Type PC COAX LT TRIAX Length in mm 01 1 mtr 02 2 mtr 05 51 2 mtr 10 10 mtr 15 15 mtr 20 20 mtr...

Page 14: ...hole fitting O rings 11x3 Electrode cable model WU20 Attention Ensure that the cable has slack remaining in the fitting so that sensor replacement is simplified To prevent damage of the O rings the nu...

Page 15: ...w end see figure 3 4 Prepare the sensors to be used in accordance with the directions for use and mount them in the fitting as shown in fig 3 4 For stable measurements the glass and reference electrod...

Page 16: ...of the electrodes see seperate sheets Parts and accessories Order nr Description FP20 S13 Mounting kit for SR20 AC32 10x K1500HC Rubber rings for FP20 S13 10x K1500GE O rings for SR20 D AC32 electrode...

Page 17: ...ows the mounting Note The pressure on the KCI solution must always exceed the liquid pressure The refillable electrodes can be connected to a KCI reservoir via a silicone tubing see figure 4 2 The pre...

Page 18: ...of cleaning systems see figure 4 3 brush cleaning electrically or pneumatically driven chemical cleaning 4 3 1 Selection criteria Cleaning system Mechanical Chemical Applications with Brush Acid Base...

Page 19: ...tem wipes across the glass membrane of the electrode every 30 seconds Electrically or pneumatically driven versions are available Figures 4 4a and 4 4b show the mounting Control unit Parts and accesso...

Page 20: ...n the liquid to be measured The cleaning period and frequency can be adjusted on a control unit The mounting procedure is shown in figure 4 5 Parts and accessories Order nr Description K1520FJ Tubing...

Page 21: ...ng set PPS Ryton O ring silicone Connection nylon Weight approx 300 g Mounting wall mounting support with hole for screw M5 Temperature pressure ratio max 200 kPa 2 bar at 100 C Parts and accessories...

Page 22: ...S K1500FC EPDM Set O rings for 3 hole fitting SS K1500GX Set O rings for 4 hole fitting SS K1500FH viton Set O rings for 4 hole fitting SS K1500FG EPDM Set O rings for 4 hole fitting SS K1500DQ 10 m p...

Page 23: ...IM12B06K02 01E E 23 1 Hole PVC Note This fitting has no liquid earth connection 3 Hole PP and PVDF 4 Hole PP and PVDF 3 Hole SS 4 Hole SS IM12B06K02 01E E_ed09 indd 23 07 03 16 09 51...

Page 24: ...awa com eu YOKOGAWA ELECTRIC CORPORATION World Headquarters 9 32 Nakacho 2 chome Musashino shi Tokyo 180 8750 Japan www yokogawa com YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan GA 30265 USA www...

Reviews: