![YOKOGAWA EJA210E User Manual Download Page 43](http://html1.mh-extra.com/html/yokogawa/eja210e/eja210e_user-manual_3756588043.webp)
<7. Operation>
7-5
IM 01C25C01-01E
7.5.1 Draining Condensate
1) Gradually open the drain plug and drain the
transmitter pressure-detector section.
(See Figure 7.2)
2) When all accumulated liquid is completely
removed, close the drain plug.
3) Tighten the drain plug to a torque of 34 to 39
N·m {3.5 to 4 kgf·m}.
7.5.2 Venting Gas
1) Gradually open the vent screw to vent gas from
the transmitter pressur-detector section.
(See Figure 7.2)
2) When the transmitter is completely vented,
close the vent screw.
3) Tighten the vent screw to a torque of 10 N·m
{1 kgf·m}.
F0705.ai
When you loosen the drain plug or the vent screw, the accumulated
liquid (or gas) will be expelled in the direction of the arrow.
Vent screw
Drain plug
Figure 7.2
Draining/Venting the Transmitter
7.5.3 Draining Condensate for Flushing
Connection Ring
1) Gradually open the drain screw to drain from
the flushing connection ring.
2) When the flushing connection ring is completely
drained, close the drain screw.
3) Tighten the drain screw to a torque of 10 N·m
{1 kgf·m}.
F0706.ai
Drain screw
When you loosen the drain screw,
the accumulated liquid(or gas)
will be expelled in the direction of
the arrow.
Figure 7.3
Draining for Flushing Connection Ring
7.5.4 Venting Gas for Flushing Connection
Ring
1) Gradually open the vent screw to vent gas from
the flushing connection ring.
2) When the flushing connection ring is completely
vented, close the vent screw.
3) Tighten the vent screw to a torque of 10 N·m
{1 kgf·m}.
F0707.ai
Vent screw
When you loosen the vent screw,
the accumulated liquid(or drain)
will be expelled in the direction
of the arrow.
Figure 7.4
Venting for Flushing Connection Ring