![YOKOGAWA EJA210E User Manual Download Page 29](http://html1.mh-extra.com/html/yokogawa/eja210e/eja210e_user-manual_3756588029.webp)
<4. Installation>
4-2
IM 01C25C01-01E
4.3 Rotating Transmitter Section
The transmitter section can be rotated
approximately 360° and can be fixed at any angle
within the above range. (The direction of the
rotation is depending on the configuration of the
instrument.) Note that there is a stopper which
prevents the transmitter section from being rotated
more than 360°.
1) Using the Allen wrench, remove the two
setscrews securing the transmitter section to
the capsule assembly.
2) Rotate the transmitter section slowly to the
desired position.
3) Tighten the two setscrews to a torque of
1.5 N·m {15 kgf·cm}.
WARNING
In the case of the explosion-proof/flameproof
type transmitter, do not rotate the transmitter part
in the hazardous area while the transmitter is
energized.
IMPORTANT
Do not rotate the transmitter section more than
the above limit.
F0402.ai
Transmitter section
Pressure-detector section
Conduit connection
Figure 4.2
Rotating Transmitter Section
4.4 Changing Integral Indicator
Direction
IMPORTANT
• Always turn OFF power and shut off and
release pressures before disassembly.
• For changing the integral indicator direction,
the transmitter must be removed to a non-
hazardous area.
An integral indicator can be installed in the following
three directions, Refer to subsection 8.4 for
attaching and removing the integral indicator.
F0403.ai
Figure 4.3
Integral Indicator Direction