![YOKOGAWA DP Harp EJX118B User Manual Download Page 91](http://html1.mh-extra.com/html/yokogawa/dp-harp-ejx118b/dp-harp-ejx118b_user-manual_3526111091.webp)
<
10. General Specifications
>
10-10
IM 01C27H01-01E
II. Diaphragm seal section (Combination type)
Process connection size: High pressure side; 4-inch (100 mm) • • • Extended type
Low pressure side; 3-inch (80 mm) • • • Flush type
T13E.ai
Model
EJX118B
Description
Transmitter body section (I)
Combination type (Extended and Flush)
Process connection style
High pressure side 4-inch (100 mm)
Low pressure side 3-inch (80 mm)
JIS S25C
JIS SUS304
JIS SUS316
Serration (for ANSI flange only)
Flat (no serration)
[Diaphragm]
[Pipe]
[Others]
High pressure side: JIS SUS316L
JIS SUS316
JIS SUS316
Low pressure side:
JIS SUS316L
—
JIS SUS316L
None
Length (X2) = 50 mm
Length (X2) = 100 mm
Length (X2) = 150 mm
[Process
[Ambient
temperature] temperature]
For general use (silicone oil)
–10 to 250°C –10 to 60°C
For general use (silicone oil)
–30 to 180°C –15 to 60°C
For high temperature use (silicone oil)
10 to 310°C 10 to 60°C
For oil-prohibited use (fluorinated oil)
*2
–20 to 120°C –10 to 60°C
For low temperature use (ethylene glycol)
–50 to 100°C –40 to 60°C
High pressure side: Back of diaphragm seal unit
Low pressure side: Side of diaphragm seal unit
Always 2
/
Optional specification
1 m
2 m
3 m
4 m
5 m
6 m
7 m
8 m
9 m
10 m
Process connection size
(Process flange size)
Flange material
►
Gasket contact surface
*1
Wetted parts material
*4
Flushing connection ring
Extension
Fill fluid
►
Capillary connection
—
Capillary length
*3
Suffix codes
A
. . . . . . . . . . . . . . . . .
B
. . . . . . . . . . . . . . . . .
C
. . . . . . . . . . . . . . . . .
1
. . . . . . . . . . . . . . . .
2
. . . . . . . . . . . . . . . .
0
. . . . . . . . . . . . .
1
. . . . . .
2
. . . . . .
3
. . . . . .
4
. . . . . .
5
. . . . . .
6
. . . . . .
7
. . . . . .
8
. . . . . .
9
. . . . . .
A
. . . . . .
-A
. . . . . . . . . .
-B
. . . . . . . . . .
-C
. . . . . . . . . .
-D
. . . . . . . . . .
-E
. . . . . . . . . .
SY
. . . . . . . . . . . . .
W
. . . . . . . . . . . . . . . . . .
1
. . . . . . . . . . . .
3
. . . . . . . . . . . .
5
. . . . . . . . . . . .
C
. . . . . . . . .
2
. . . . . . . .
-Y
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
Option codes
F1007.ai
EJX118B
Y
W
JIS 10K
JIS 20K
ANSI class 150
ANSI class 300
JPI class 150
JPI class 300
DIN PN10/16
DIN PN25/40
Flange rating
J1
. . . . . . . . . . . . . . . . . . .
J2
. . . . . . . . . . . . . . . . . . .
A1
. . . . . . . . . . . . . . . . . . .
A2
. . . . . . . . . . . . . . . . . . .
P1
. . . . . . . . . . . . . . . . . . .
P2
. . . . . . . . . . . . . . . . . . .
D2
. . . . . . . . . . . . . . . . . . .
D4
. . . . . . . . . . . . . . . . . . .
The “►” marks indicate the most typical selection for each specification. Example: EJX118B-LMSCG-98JDN-YA1WB1SY01-BC25/
*1:
See table 10.3 ‘Gasket contact surface.’
*2:
Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and
dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
*3:
The specified capillary length of high pressure side (extended side) includes the extension length (X2) and the flange thickness (t).
*4:
!
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of
inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant
facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid
can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite,
and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.