<2. Handling Cautions>
2-8
IM 01C27H01-01EN
(2) Technical Data
Article 4, Paragraph 3 of PED, denoted as
Sound Engineering Practice (SEP).
(3) Operation
CAUTION
• The temperature and pressure of fluid should
be maintained at levels that are consistent
with normal operating conditions.
• The ambient temperature should be
maintained at a level that is consistent with
normal operating conditions.
• Please take care to prevent water hammer
and the like from inducing excessive
pressures in pipes and valves. If phenomena
are likely, install a safety valve or take
some other appropriate measure to prevent
pressure from exceeding PS.
• Take appropriate measures at the device or
system level to protect transmitters if they
are to be operated near an external heat
source.
2.11 Low Voltage Directive
Applicable standard:
EN61010-1, EN61010-2-030
(1) Pollution Degree 2
"Pollution degree" describes the degree to
which a solid, liquid, or gas which deteriorates
dielectric strength or surface resistivity is
adhering. " 2 " applies to normal indoor
atmosphere. Normally, only non-conductive
pollution occurs. Occasionally, however,
temporary conductivity caused by condensation
must be expected.
(2) Installation Category I
(Anticipated transient overvoltage 330 V)
"Overvoltage category (Installation category)"
describes a number which defines a transient
overvoltage condition. It implies the regulation
for impulse withstand voltage. " I " applies to
electrical equipment which is supplied from the
circuit when appropriate transient overvoltage
control means (interfaces) are provided.
2.12 Regulatory Compliance
for Radio and
Telecommunication
Please confirm that a installation region fulfils a
standards, require additional regulatory information
and approvals, contact to Yokogawa Electric
Corporation.
2.12.1 Radio and Telecommunications
Terminal Equipment Directive
(R&TTE)
We, Yokogawa Electric Corporation hereby declare
that this equipment, model EJX-L series is in
compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC.
The CE declaration of conformity for R&TTE for this
product can be found at
http://www.yokogawa.com/
fld/
2.12.2 FCC compliance
This equipment contains transmitter module FCC
ID: SGJ-WFC001.
This device complies with Part 15 of FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2)
this device must accept any interference, including
interference that may cause undesired operation of
this device.
Co-located:
This transmitter must not be co-located or operated
in conjunction with any other antenna or transmitter.
FCC WARNING:
Changes or modifications not expressly approved
by the party responsible for compliance could void
the user’s authority to operate the equipment.