YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

LIMITED PRODUCT WARRANTY POLICIES

The YMGI products are designed and manufactured free from defects in workmanship, and materials for normal 
use. However, for any reason, including many handlings and occasions between the YMGI factories/warehouses 
and where you receive the products, the unit doesn't work, YMGI Group will help to remedy the occurrence in the 
following warranting ways:  

Compressor: 

YMGI will warrant the compressor of YMGI-validated and approved warranty filing, for a period of 

5 years from the date of successful installation at original location.

Parts: 

YMGI will warrant parts of YMGI-validated and approved warranty filing, for one year from the date of 

successful installation at original location.  

All warranty compressors and parts replaced will become the sole property of YMGI Group and must be returned 
to YMGI Group upon request.  Warranty parts may be new or refurbished. All parts are tested and approved 
before shipping.

At no time does the YMGI Group warrant labor cost of any type. Warranty will start from the date of 
successful installation at initial location, or 90 days as of original shipping date from YMGI Group, 
whichever comes first.
This is a standard warranty of limited liability and DOES NOT cover the following:

* Any damage or repairs to properties, or persons as an incident or consequence of improper or faulty 
  transportation, installation, operation, maintenance or service.
* Damage caused by frozen or broken water hoses or refrigeration pipes in the event of equipment failure.
* Any damage as a result of floods, fire, wind, lightening, accidents, corrosive atmosphere or any other conditions 
  beyond the control of YMGI Group.
* Any damage due to interruption or inadequate electrical service to equipment.
* Any products that are installed outside the US or Canada.
* Any unit that has been moved from the original installation address.
* Any labor costs associated with the installation or service of the unit.
* Poor unit performance due to improper unit selection (SEER, Unit size).

To validate the above warranties, ALL the following conditions must all be fulfilled:

1. The unit was fully (100%) and successfully installed by licensed or certified HVAC technicians.
2. The unit was installed following all NEC, state and local codes.
3. The unit was installed following all instructions and manuals made by YMGI Group.
4. ALL fields, especially the technician-checklist, of the 

Limited Warranty Registration Card/Form

 were filled 

    completely by the installing technician and signed by both the installing company technician and the unit owner.
5. The 

Limited Warranty Registration Card/Form

 and a copy of the original installing company's invoice had 

    been received by YMGI Group-Warranty Dept., POB 1559, O'Fallon, MO 63366, within 7 days of successful 
    installation.

No warranty filing will be validated or approved, if any one of the above 5 conditions is not met.
Product registration doesn't guarantee the validity of this limited warranty statement.

Steps to follow for warranty part replacement:

1. Installing or service technician contacts YMGI tech support at 1-866-833-3138 ext 703 from the jobsite, to 
    double-check and confirm with YMGI Technical support the exact part(s) needed to fix all the problems.
2. YMGI will check the customer's warranty filing. Parts for validated and approved warranty will not be charged. 
    Parts of invalid warranty filing or unapproved warranty requesting, will be charged accordingly.
3. YMGI will ground ship out the parts ASAP. Expedited shipping is available at the customer's cost.
4. Replacement parts of approved warranty registration are to be warranted for the remainder of the 1 year parts 
    and 5 year compressor warranty. Purchasing of replacement parts of invalid warranty filing or unapproved 
    warranty requesting, will be as they are and bear no warranty.

YMGI keeps on improving products with various engineering changes without prior notice.  Such improvements 
or changes include but not limited to product specification, appearance, functions, sizes, packaging and others.  
These improvements or changes will not void the limited warranty stated herein. YMGI keeps the final explanation 
of this warranty policy.

W

ARRANTY

 POLICIES 

AND REGISTRA

TION 

CARD/FORM

P6 OF 32

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

LIMITED PRODUCT WARRANTY REGISTRATION CARD

LIMITED PRODUCT WARRANTY

REGISTRATION CARD / FORM  

YMGI to Fill Top Portion, at Shipping, and Keep Copy A; Center Copy B for Installer to Fill and Mail back to YMGI; Bottom Copy C for Customer to Fill and Keep 

Installation Finished and Unit Works Successfully.
Print Name of Installation HVAC Technician:
Signature:

Date and time:

Installation Finished and Unit Works Successfully.
Print Name of Owner:
Signature:

Date and time:

1) Are you the only one to install whole system?
    If not,            % of installation done by you (HVAC technician).

3) Did you read the User Manual and Installation Instruction, before you 
    started the installation?

5) Supply electrical power V/Ph/Hz measured at wiring terminal block of 
    Indoor unit:                                  outdoor unit:

7) Wire gauge, length and terminal colors between circuit breaker/
    disconnect switch to outdoor unit:

9) The size of HVAC circuit breaker/fuse or disconnect switch to the 
    outdoor unit:

11) What is the refrigerant pipe length between each indoor unit and the 
      outdoor unit? Unit A                 Unit  B              Unit C               Unit D...

13) What is the elevation difference between each indoor unit and the 
      outdoor unit? Unit A                 Unit  B              Unit C               Unit D...
     (indoor unit above outdoor unit +, below -)

15) Where is the outdoor unit located? 
      Ground  wall balcony  roof  other 
      location or pad

17) Were the refrigerant pipe ends capped or taped seal, prior to running 
      them through structures to keep debris from entering the copper lines?

21) Did you check if the compressor can be started and stopped in a 
      correct (design) manner?

25) Have you checked all unit functions, with customer's witness, and all 
      functions are correct?

27) Do you provide regular one-year free technical service for this 
      installation?

2) What had been done, prior to your arrival?

4) Who unpacked the unit and accessory boxes to check for damage?

6) Incoming electrical power V/Ph/Hz measured at terminal blocks of
    indoor unit:                                   outdoor unit:

8) Wire gauge, length and terminal colors between each indoor and 
    outdoor unit: Unit A                 Unit  B              Unit C                    Unit D...

12) Where is/are the indoor unit(s) located?
      Unit A                   Unit  B                Unit C                  Unit D...

16) Have you checked to make sure there is no cross-piping and no 
      cross-wiring between any two indoor units (zones)? How did you do it, 
      who was with you?

22) If copper length were not made to the supplied or recommended 
      refrigerant pipe length, how much refrigerant added or deducted?

26) Did you show the user how to operate the unit? Did he/she understand you?

Contact Where the Units are Installed:

Name:
Address:
City:

State (Province):

Contact of the Installing HVAC Contractor/Technician:

Technician Full Name (Print):

HVAC Technician's Company Name:

Address:
Currently Licensed or Certified HVAC Technician License or Certification Number:

Official Phone # to Check the License Validity:

Phone:

Fax:

Email:
Country:

YMGI-Recommended Contractor/Technician:

Phone:Fax:

Email:
City:State (Province):

License Approved or Certified by:

The Company the 
Unit Was Sold Though:

Did the Company 
Pay to YMGI:

Installation Invoice Attached 
to the Registratio Card

For 

YMGI 

Use 

Only

Unit #5
Unit #6
Unit #7
Unit #8

Outdoor Serial Number (One Outdoor 
Unit, One Registration Card/Form):

Indoor 

Serial 

Number:

For Multi 

Zone Units

Unit #1
Unit #2
Unit #3
Unit #4

Shipping Packing 
List Number:

Registration Card 
Serial No.

Date the Filled Registration 
Card YMGI Received:

Unit(s) Work 
Successfully (Yes/No):

Warranty 
Approved 

Warranty 
Denied

18) Have you checked and run cooling or heating, one unit by one unit, all 
      working fine?

20) Did you vacuum correctly to check the connecting pipes and indoor unit for
      leakage, what was the micron gauge reading, for how many minutes?

24) What were the measured temperatures (probe not touching any metal):

O

O

O

      At cooling: indoor return air       F,  discharge air       F, and outdoor         F

O

O

O

      At heating: indoor return air       F,  discharge air       F, and outdoor         F

23) Measured refrigerant pressures at outdoor service suction valve, when unit 
      was st. 

O

      Heat pump (PSI):      Cooling (PSI):         Outdoor Ambient Temp. ( F):

HVAC Contractor/
Technician--Name

Hired YMGI-Recommended 
HVAC Contractor/Technician?

List for Installating HVAC Technician to Double Check Installation Quality, and Warranty Processing Purpose (if not filled by technician, or not filled fully, warranty will void)

10) Are the inter-connecting wires and copper lines between indoor and outdoor 
     units installed/covered/protected by line set covers, or anything else? 

14) Did you check the indoor unit for condensate leakage and refrigerant 
      leakage, before and after connecting them?

28) Do you list the working details in the invoice and leave a copy to the 
      customer?

19) Did you charge the inter-connection copper pipes and indoor unit with 
      nitrogen to check for positive leakage (pressures 150-200PSI), before 
      conducting vacuuming leakage check?

By signing above, I acknowledge the liability and responsibility for any false statement or not telling all the facts, and I authorize YMGI to check the details of the filled above, and make its 
decision on warranty. I understand our filing or filling the warranty card/form DOESN'T mean automatic warranty approval, because warranty is approved only to those qualified and successful 
installations by qualified HVAC technician. I know the warranty, if approved, is a standard 5-year compressor and 1-year other parts only, without any labor coverage. I agree to and will follow 
all the contents contained in the Limited Product Warranty Policy that YMGI, not other entity, stated in public, including but not limited to manuals, web site, email, etc.
Important Note: A copy of the installing HVAC company's invoice to show all their work details, your payment proof, center copy B of this registration card filled after a successful 
installation, all three (3) MUST be mailed together to Warranty Dept., 

YMGI Group, POB 1559, O'Fallon, MO 63366

, for warranty processing. Customer keeps bottom copy C. YMGI 

will check against copy A that was kept at YMGI.

Is the outdoor unit anchored to 
ground or secured onto wall 
bracket?

Summary of Contents for SYMPHONY CHOIR 80CH

Page 1: ... Installation operation maintenance and service shall follow professional practices for regular cooling and heating equipment NEC State City or Local Codes and related manuals from us Otherwise damage to equipment or property even injury to people may occur Installer Currently licensed HVAC installer only Read this manual before installation Sign on the warranty registration card User Keep this ma...

Page 2: ...ORTANT NOTE YMGI HOLDS FINAL EXPLANATION The quality of the installation plays a key role in whether the units will work well and for an extended period of time The information we provide in our manuals is for the sole purpose of reminding you and your installer It is our ultimate goal to help insure that your YMGI units are installed properly and correctly from the very beginning to the very end ...

Page 3: ...re humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jobs and list them in your proposal quote in writing on your company s quote form or letter head basing upon the information you get from 1 2 and 3 above 5 List your currently valid HVAC license and EP...

Page 4: ... the installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to outdoor unit 9 The size of HVAC circuit breaker fuse or disconnect switch to the outdoor unit 11 What is the refrigerant pipe length between each indoor unit and the outdoor unit Unit A Unit B Unit C U...

Page 5: ... the tools to do these calculations correctly and get your approval before purchasing the air conditioner or heat pump equipment Any problems due to improper installing of the air conditioner heat pump system Installation should be conducted by currently licensed HVAC technician following manufacturer installation instructions all governing safety codes with care and professionalism Any problems d...

Page 6: ...the appointed service center A place which is full of machine oil A region with saline sodic soil near the sea A place where the sulphide fog exists such as the sulphur spring A place where the high frequency facilities exist such as radio equipment electric welder and medical equipment An environment with special conditions 1 When the place of the installation is exposed to strong wind When stron...

Page 7: ...is strength and level so that the unit will not cause any operating vibration or noise after installation 2 In accordance with the foundation drawing in the Fig 6 please drill 4 holes in the installation location A Discharge air side B Bottom view inches C Drain holes 3 Fix the unit securely with the foundation bolts You can get the M10 or M8 foundation bolts nuts and washers from the market 4 Rub...

Page 8: ...RANT PIPES Y type branch pipe must be installed in vertical or horizontal direction In the inlet of the branch pipe keep at least 19 69inch straight pipe 1 Pipe connections should be follow the following rules Outdoor unit shall be installed close to the indoor unit hence to minimize the length and bends of connection pipes The gap of outdoor unit and indoor units should be as small as possible Th...

Page 9: ...e operation 2 As shown in the following figure expel the gas from the refrigerant pipes by the vacuum pump 3 Open the pump and turn on the knobs to evacuate the gas in the liquid and gas pipes 4 When the pressure of the system is less than 0 1Mpa 1bar keep the system for more than one hour under the condition 5 Then turn off the knobs and the pump and if the pressure of the pressure vacuum gauge d...

Page 10: ...sure vacuum gauge 6 7 8 9 Hi knob Lo knob R410A tank Scale When the liquid and gas stop valves have not been opened the system is under the vacuum 1 Refer to the left of the Fig 20 connect the R410A tank to the system 2 Turn on the R410A tank and the Hi knob charge the R410A refrigerant into the system from the liquid side stop valve The Lo knob should be closed completely 3 Turn off the R410A tan...

Page 11: ...ground terminal should be provided and the ground wire cannot be connected to any of the following places a Water pipe b Coal gas pipe c Sewage pipe d Lightning rod e Telephone line f Other unreliable places considered by a professional ELECTRICAL WIRING WORK The ground connection should be reliable and the ground wire should be connected to the dedicated device of the building by the professional...

Page 12: ... or outdoor unit is blocked Remove the obstacles Air inlet or outlet of indoor unit or outdoor unit is blocked Remove the obstacles Temperature setting is improper Adjust the setting of remote controller or wire controller Air speed is set too low Adjust the setting of remote controller or wire controller Improper airflow direction Adjust the setting of remote controller or wire controller Door or...

Page 13: ... board of the outdoor unit Check for more details about the meaning of each error Conditions Causes When restart the unit soon after it is stopped The overload protection switch of the unit let the startup delayed for three minutes As soon as power supply is on The unit will stand by for approximate one minute When the cooling operation starts The hi humidity air indoor is cooled quickly The unit ...

Page 14: ...ing to include a 1 year installation service warranty at no extra charge Check with them to see if that is available If available include that in the contract 14 Verify and confirm the installation is done completely and all the unit functions have been checked and are working properly all the items in the checklist have been checked and marked well in the warranty registration card form prior to ...

Page 15: ...e exceptions Most have resulted in equipment failure due to lack of knowledge and experience A few of the problems result from DIY s lack of knowledge in the following areas Sizing and selecting correct type size and model of cooling and or heating equipment Sizing and installing correct electric circuit breakers and wires Wiring the units correctly and properly Taping the ends connecting to indoo...

Page 16: ...different from what are typical in traditional split type air conditioning and heat pump systems and similar systems made by other manufacturers These are not defects Take some time to learn the functions of your unit We will be happy to assist you with any questions you may have concerning the functions of your new unit 1 Part repair or replacement after trouble shooting This is the most common a...

Page 17: ...ND INSTALLATION SERVICE MAINTENANCE NOTES Notes Asked for Your Technician for Help Did You Ask YMGI Tech for Help INSTALLATION NOTES Original Installation Company Name Technician Name Phone HVAC License Job Not Performed by Technician Technician Checklist Completed Fully SERVICE MAINTENANCE NOTES No Date Contents of Service Maintenance Technician s Company Name Technician Name Phone HVAC License P...

Reviews: