YMGI M2 SERIES Installation Instruction Download Page 8

BRIEF UNIT INFO

BRIEF UNIT INFO

P14 OF 44

P13 OF 44

BEFORE INSTALLATION IDENTIFY COMPONENTS

Unit Appearance and Specifications Are Subject to Change for Continuous Improvement without Any Prior Notice.

INDOOR UNIT

Air Inlet

Air Intake Grilles

Temperature Sensor

Indicating Lamp &
Signal Receiving
Window

Emergency Switch

Horizontal Louver

Vertical Louver

Air Outlet

Air Filter

Remote Control

Air Inlet   

Connecting Pipe 
and Cable

Drainage Hose

Air Outlet

OUTDOOR UNIT

Mini Split Wall Mount Systems are designed for high performance, easy installation and service. Each system 
consists of one or several indoor units and one outdoor unit, which are connected by one set or several multiple 
sets of interconnection refrigerant pipes and electric wires.

As shown in the following sample picture of outdoor unit, air is drawn through the coil from the rear side and then 
discharged from the front side. In cooling mode, air passing through coil is heated; in heating mode, air passing 
through coil is cooled.

Sample Wall Mount Mini Split System (For Continuous Engineering Improvement and Various Marketing 
Needs and Actual Part Availability Reason, Unit Appearance Subject to Change or Update Continuously 
without Prior Notice)

Outdoor unit(s) provides the electrical and thermal power for the whole system. Electrical and thermal 
components such as compressors and motors and heat exchange coils and others, are incorporated into the 
cabinet in an optimized order. They can be either hung on the wall or installed on the ground. Once stacking or 
bracket kit is used, some outdoor units can be stacked 2 or 3 units high, upon unit size and applications. Air is 
discharged horizontally, quietly and smoothly. These units are perfect fit in locations where installation and 
applications of general up-flow condensing units are limited, such as apartments, condos, lofts, multi-families and 
high-rise buildings and others named or unnamed.

Indoor unit(s) delivers the thermal and acoustical comfort to the rooms. Air is drawn through the coil from the 
front or topside and then discharged from the bottom. In cooling mode, air passing through coil is cooled; in 
heating mode, air passing through coil is heated. Air is filtered or treated by the built in mechanism (washable or 
enzyme equipped or electrostatic powered filter, varies from model to model), before being delivered into the 
room, with more than enough comfort and care, at a wide angle (swing or not, varies from model to model).

Air In

Air Out

BRIEF INTRODUCTION TO MINI SPLIT WALL MOUNT SYSTEM

NOTES: 

Since ductless system is not designed to incorporate or use with ducted return or discharge tunnels, one 

single-zone unit SHALL NOT be used to take care of the cooling or heating load of more than one-story room. 
Several single-zone ductless systems or multiple-zone ductless systems shall be proper in this regard.

These units are designed for applications at:

* Residential
* Light commercial

* Commercial
* Hospital

* Institutional
* Industrial

Apartments

Office Buildings                

Homes

Application Samples of Wall Mount Mini Split Systems

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Summary of Contents for M2 SERIES

Page 1: ...his product is designed and manufactured free from defects in material and workmanship under the normal use and maintenance Installation operation maintenance and service shall follow professional pra...

Page 2: ...y parts may be new or refurbished All parts are tested and approved before shipping At no time does the YMGI Group warrant labor cost of any type Warranty will start from the date of successful instal...

Page 3: ...nit for condensate leakage and refrigerant leakage before and after connecting them 28 Do you list the working details in the invoice and leave a copy to the customer 19 Did you charge the inter conne...

Page 4: ...roperly can be more expensive than spending the little extra money that hiring the right contractor will cost Protect your investment and warranty eligibility by doing it right the first time THE FOLL...

Page 5: ...e ability to claim freight damage is lost and YMGI will not replace the unit on this basis Contact the distributor or YMGI report the damage by forwarding the marked delivery receipt copy and pictures...

Page 6: ...Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back to the YMGI Group 3 Once the form has been completed and sent bac...

Page 7: ...ed to keep from cold air blowing into propeller fan blade against airflow and so help unit work better in both AC cooling and HP heating mode in colder weather ranges IMPORTANT NOTES FOR UNIT OPERATIO...

Page 8: ...n the ground Once stacking or bracket kit is used some outdoor units can be stacked 2 or 3 units high upon unit size and applications Air is discharged horizontally quietly and smoothly These units ar...

Page 9: ...X24K 32B WMMS 2X30K 32B WMMS 09E F 32B WMMS 09 12E F 32B WMMS 12E F 32B WMMS 18E F 32B WMMS 24E F 32B WMMS 30E F 32B WMMS 2X09C 32B WMMS 0912C 32B WMMS 2X12C 32B WMMS 2X18C 32B WMMS 2X24C 32B WMMS 2X3...

Page 10: ...4K 2 30K 3 09K 2 12 18K 3 12K 2 18 24K 2 09 12K 2 09 12 K 2 12 24K 3 12 24K Varies Varies Varies UNIT ENGINEERING SUBMITTALS MECHANIAL 09K 12K W H D 30 9 36 2 10 6 10 6 7 8 7 9 18K 24 36K 40 2 12 4 9...

Page 11: ...thly without any abnormal noise or restriction 4 Fan wheel roration at outdoor unit should rotate freely and smoothly without any abnormal noise or restriction 5 No kinking or other leaking potentials...

Page 12: ...ctricians only following NEC codes and manufacturer instructions CONNECTION OF WIRES SINGLE ZONE WIRING AT INDOOR UNIT AND OUTDOOR UNITS Open the front cover panel Remove screws from electrical box co...

Page 13: ...taken into consideration when the connections of power cable are made such as the ambient temperature direct exposure to heat dirext exposure to sunlight The specifications for the power cable refer...

Page 14: ...CLEARANCE REQUIRED AROUND UNITS SINGLE ZONE CLEARANCE REQUIRED AROUND UNITS DUAL ZONE Indoor unit B Indoor unit A SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainabl...

Page 15: ...ndoor unit C SYSTEM LAYOUT INSTALLATION CLEARANCE Indoor unit A Indoor unit B Indoor unit C Indoor unit D SYSTEM LAYOUT INSTALLATION CLEARANCE YMGI Engineered Comfort Products for A Sustainable and Ef...

Page 16: ...screws Align mounting plate holes with those holes drilled on the wall and put anchors or screws into the holes to secure mounting plate STEPS TO MOUNT PLATE a b c Drill mounting holes to make sure a...

Page 17: ...rear side of plastic casing Snap the plastic casing bottom into the mounting plate gently Sealed with putty Secure the piping wiring set with clamp Trim the extra portion 2 in or less from floor 18 18...

Page 18: ...35 45 CONNECT REFRIGERANT PIPES BETWEEN INDOOR AND OUTDOOR UNITS Firstly connect copper tubes at indoor unit Bend pipes by tools but not by hands Extra length is needed for future service REFRIGERANT...

Page 19: ...ipes Over length soft pipes will lead to irregular bending Undersize bending will damage the soft pipe Short soft pipes will have them bending undersize it s not allowed INLTS STRT COUP COUP H OFST EL...

Page 20: ...ks 1 Blink lit for 0 5 sec then off for 0 5 sec then lit for 0 5 sec 2 E4 Code Outdoor ambient temperature is too low do not to run unit during severe cold weather Refrigerant at low level users need...

Page 21: ...hnician to make appointment with YMGI tech support and call us while the techician is at job site 4 Better to check the unit get problems and model model and serial ready before calling YMGI tech supp...

Page 22: ...STALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS IMPORTANT NOTES FOR INSTALLATION OF MULTIPLE ZONE SYSTEMS MULTIPLE COMPRESSORS YMGI Engineered Comfort Products for A Sustainable and Efficient...

Page 23: ...original licensed installer or current service contractor should be contacted first of all since they installed the unit and or know more details than anybody else They will check the unit and find o...

Reviews: