In  order  to  reduce  the  potential  for  electrical  and  thermal  shock,  Yingli  Solar 

recommends cleaning PV modules during early morning or late afternoon hours 

when solar radiation is low and the modules are cooler, especially in regions with 

hotter temperatures. 

Never attempt to clean a PV module with broken glass or other signs of exposed 

wiring, as this presents a shock hazard.

Clean the glass surface of the PV modules with a soft brush using soft, clean 

water (PH6-9) with a recommended pressure less than 690kPa, which is typical 

of  most  municipal  water  systems.  Water  with  high  mineral  content  may  leave 

deposits on the glass surface and is not recommended.

Yingli Solar PV modules may contain a hydrophobic anti-reflective coating on 

the glass surface to enhance power output and reduce dirt and dust buildup. In 

order to avoid module damage, do not clean PV modules with a power washer 

or pressure washer. Do not use steam or corrosive chemicals to facilitate the 

cleaning of modules. Do not use aggressive tools or abrasive materials that could 

scratch or damage the glass surface. Failure to comply with these requirements 

may adversely affect the PV module performance. 

Yingli Solar PV modules are designed to withstand high snow loads. However, if 

removing snow is desired to enhance production, use a brush to gently remove 

snow. Do not try to remove frozen snow or ice from PV modules. 

D E C O M M I S S I O N I N G

The dismantling of PV systems must be performed with the same care and safety 

precautions  used  during  the  initial  installation.  The  PV  system  can  generate 

hazardous voltage even after the system has been disconnected. Follow safety 

regulations for working with live electrical equipment.

R E C Y C L I N G

Yingli  Solar  is  a  member  of  PV  Cycle,  the  European  association  for  voluntary 

take  back  and  recycling  of  PV  modules.  Please  contact  PV  Cycle  at  www.

pvcycle.org for details regarding the recycling process.

Meaning of crossed 

out wheeled dustbin:   

Do  not  dispose  of  electrical  appliances  as  unsorted  municipal  waste,  use 

separate collection facilities.

Contact your local government for information regarding the collection systems 

available.

If  electrical  appliances  are  disposed  of  in  landfills  or  dumps,  hazardous 

substances can leak into the groundwater and get into the food chain, damaging 

your health and well-being.

When replacing old appliances with new ones, the retailer is legally obligated to 

take back your old appliance for disposals at least free of charge.

Summary of Contents for YLM 144CELL 182PERC

Page 1: ...ication requirements has been verified by an independent certification laboratory This Installation and User Manual is available in different languages In cases of discrepancy between versions the Eng...

Page 2: ...ng so may degrade performance or cause irreparable damage and will void any applicable warranties If it is necessary to store PV modules prior to installation the PV modules should remain inside the p...

Page 3: ...suitable cross sectional areas that are approved for use at the maximum short circuit current of the PV module Yingli Solar recommends installers use only sunlight resistant cables qualified for dire...

Page 4: ...ult in galvanic corrosion An addendum to UL Standard 1703 Flat Plate Photovoltaic Modules and Panels recommends metal combinations not exceed an electrochemical potential difference of 0 5 Volts The f...

Page 5: ...hment Figure 12 Installation rails The large size modules are mounted with four outer holes with max mechanical loads of 5400 Pa snow front and 2400 Pa wind back Top down Clamps Third party clamps tha...

Page 6: ...e materials that could scratch or damage the glass surface Failure to comply with these requirements may adversely affect the PV module performance Yingli Solar PV modules are designed to withstand hi...

Page 7: ...l characteristics are within 10 percent of the indicated values of Isc Voc and Pmax under Standard Test Conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 Refer to module...

Page 8: ...f 14 20 N m The tightening steps as follows use torque wrench to tighten nut to target torque nut loosen 90 180 degrees finally tighten the nut to the target torque and reduce the torque attenuation 2...

Page 9: ...ashers of minimum 1 4 mm thickness with an minimum outer diameter of 15 57 mm Modules can be attached using the mounting holes the number of mounting holes used for a single long side frame 2 includin...

Page 10: ...when it is pressed down L represents the length of the long side of the module the described distances are from the module edge to the middle of the clamp The long side frames of the module are fixed...

Page 11: ...ropes are required to secure the modules to the forklift with a tensile strength greater than 2000 kgf 2 Pass the forearm of the anti tilting bracket through the pallet insert the two bolts into the...

Reviews: