Service h86-312-8922216    

                                 

 

120 cell module 

Type 

position L/mm 

Max mechanical load 

Long frame type-1 

350

470 

front 5400Pa 

back 2400Pa 

Long frame type-2 

350

470 

front 2400Pa 

back 2400Pa 

0

250 

front 1600Pa 

back 1600Pa 

short frame type-1 

0

250 

front 1600Pa 

back 1600Pa 

 

144 cell module 

Type 

position L/mm 

Max mechanical load 

Long frame type-1 

350

550 

front 5400Pa 

back 2400Pa 

Long frame type-2 

350

550 

front 2400Pa 

back 2400Pa 

0

250 

front 1000Pa 

back 1000Pa 

short frame type-1 

0

250 

front 1000Pa 

back 1000Pa 

 

 

 

 

 

 

Table 2: Clamps mounting range

M A I N T E N A N C E

General

Yingli Solar recommends that PV systems be periodically inspected by the 
installer, or other qualified person. 

The purpose of the PV system inspection is to ensure that all system 
components are functioning properly. At a minimum, this inspection should 
confirm the following:

–  All cables and connector attachments are undamaged and properly secured

– No sharp objects are in contact with the PV module surfaces

–  PV modules are not shaded by unwanted obstacles and/or foreign material

–  Mounting and grounding components are tightly secured with no corrosion

Defects should be addressed immediately. 

 

Cleaning

Over time, dirt and dust can accumulate on the glass surface of the module, 
reducing its power output. Yingli Solar recommends periodic cleaning of PV 
modules to ensure maximum power output, especially in regions with low 
precipitation. 

In order to reduce the potential for electrical and thermal shock, Yingli Solar 
recommends cleaning PV modules during early morning or late afternoon hours 
when solar radiation is low and the modules are cooler, especially in regions 
with hotter temperatures. 

Never attempt to clean a PV module with broken glass or other signs of exposed 
wiring, as this presents a shock hazard.

Clean the glass surface of the PV modules with a soft brush using soft, clean 
water (PH6-9) with a recommended pressure less than 690kPa, which is 
typical of most municipal water systems. Water with high mineral content may 
leave deposits on the glass surface and is not recommended.

Yingli Solar PV modules may contain a hydrophobic anti-reflective coating on 
the glass surface to enhance power output and reduce dirt and dust buildup. In 
order to avoid module damage, do not clean PV modules with a power washer 
or pressure washer. Do not use steam or corrosive chemicals to facilitate 
the cleaning of modules. Do not use aggressive tools or abrasive materials 
that could scratch or damage the glass surface. Failure to comply with these 

requirements may adversely affect the PV module performance. 

Yingli Solar PV modules are designed to withstand high snow loads. However, if 
removing snow is desired to enhance production, use a brush to gently remove 
snow. Do not try to remove frozen snow or ice from PV modules. 

D E CO M M I S S I O N I N G

The dismantling of PV systems must be performed with the same care and 
safety precautions used during the initial installation. The PV system can 
generate hazardous voltage even after the system has been disconnected. 
Follow safety regulations for working with live electrical equipment.

R E C YC L I N G

Yingli Solar is a member of PV Cycle, the European association for voluntary 
take back and recycling of PV modules. Please contact PV Cycle at www.
pvcycle.org for details regarding the recycling process.

Meaning of crossed –out wheeled dustbin:   

Do not dispose of electrical appliances as unsorted municipal waste, use 
separate collection facilities.

Contact your local government for information regarding the collection systems 
available.

If electrical appliances are disposed of in landfills or dumps, hazardous 
substances can leak into the groundwater and get into the food chain, damaging 
your health and well-being.

When replacing old appliances with new ones, the retailer is legally obligated to 
take back your old appliance for disposals at least free of charge.

Summary of Contents for YL365D-34d 1/2

Page 1: ...n laboratory This Installation and User Manual is available in different languages In cases of discrepancy between versions the English language version shall control Failure to comply with the requir...

Page 2: ...g so may degrade performance or cause irreparable damage and will void any applicable warranties If it is necessary to store PV modules prior to installation the PV modules should remain inside the pa...

Page 3: ...that are approved for use at the maximum short circuit current of the PV module Yingli Solar recommends installers use only sunlight resistant cables qualified for direct current DC wiring in PV syst...

Page 4: ...corrosion An addendum to UL Standard 1703 Flat Plate Photovoltaic Modules and Panels recommends metal combinations not exceed an electrochemical potential difference of 0 5 Volts The frame rails have...

Page 5: ...0 cell module is mounted with four inner holes and the 144 cell module is mounted with four outer holes with max mechanical loads of 5400 Pa snow front and 2400 Pa wind back Top down Clamps Third part...

Page 6: ...wiring as this presents a shock hazard Clean the glass surface of the PV modules with a soft brush using soft clean water PH6 9 with a recommended pressure less than 690kPa which is typical of most m...

Page 7: ...cent of the indicated values of Isc Voc and Pmax under Standard Test Conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 C Refer to module datasheets for specific power out...

Page 8: ...E SERIES WITH 35MM FRAME CONT UNITS mm YLM 120 Cell half Cell also valid for YLM 120 cell half cell 1500V Frame Cross Section Legend Legend Grounding holes Mounting holes Drainage holes Mounting toler...

Reviews: