9
The gearbox maintenance (oil change / check) must be done according this manual.
4.2- Transportation
When the gearbox arrive, first check for any damage. If some damage observed, im-
mediately contact the transport company and inform about damage. Contact YILMAZ
for the damage and do not start installing the gear unit until it is agreed that the dam-
age has no affect of operation.
Use the supplied eyebolts or lifting holes for lifting up the gear unit. The eyebolts are
capable to carry the weight of gearboxes only. Do not hang additional loads.
4.3- Storage
If the geared unit or geared motor will be stored up to 3 years refer to the following
instructions ;
With Packing ;
- Use corrosion protection oil for the output shaft and connection surfaces like flange
surface or foot assembling surface. Seal the unit in a plastic wrap and pack it in con-
tainer. A moisture indicator should be placed around the container to observe the mois-
ture. Relative atmospheric humidity should not exceed 50%. The container should be
kept under roof which protects from snow and rain. Under this condition the gear unit
can be stored up to 3 years with regular check.
Without Packing ;
- Use protection oil for the output shaft and connection surfaces like flange surface or
foot assembling surface. If no packing is used and the gearbox is stored without pack-
ing, the ambient temperature should be between 5 to 60 Celsius degrees. The gearbox
must be kept under enclosed roof with constant temperature and constant humidity not
exceeding 50%. The storage should be free of dust and dirt and ventilated with filter. If
the gearbox is stored without packing it is recommended not to store more than 2 years
and regularly checking is recommended during this time.
If stored in open protect against insect damage.