M240 V4 Series IP MODEM User Manual
Add:Floor 14,A06 building, No.370,Chengyi Street,Jimei District, Xiamen,China.
Web: www.yifanwireless.com H86 592 6101492 Fax:+86 592 5222813
23
/
35
CALL Phone No.
Any phone number call can wake up IP Modem, if the trigger number
is empty. Otherwise only the trigger phone number call can trigger
the IP Modem.
SMS Phone No.
Any phone number’s SMS can wake up IP Modem, if the trigger
number is empty. Otherwise only the trigger phone number’s SMS
can trigger the IP Modem.
Data Trigger On
Online data
Data Trigger Off
Offline data
Trigger Port
Set the trigger data source from PORT1 or PORT2
Data Format
Format of the trigger data: Text or HEX
3.3.3.3 Debug Level
Debug information is used to debug software when there is software problem.
Debug Level
Close
:
no debug information output
Level 1
:
simple prompt information output
Level 2
:
detail debug information output
Debug Port
Port 1
:
debug info send to port 1
Port 2
:
debug info send to port 2
485
:
debug info send to RS485
3.3.3.4 Clear Serial Buffer
Whe
n open “clearing Serial buffer” function, serial port data before connecting to the network
will not be sent to the center
3.4 Data Service Center Settings
Settings on this page are the parameters related to Data Service Center (DSC).