Yeticool TX95B User Manual Download Page 6

Restoring the default settings of the application

Disconnecting the Bluetooth connection

 Device on/off button

Setting the 

max

 temperature

Setting the m

in

 temperature

Setting the compressor start delay after starting the device (in minutes)

Left ventricular hysteresis setting - the compressor will start after exceeding the sum of the
set device temperature and hysteresis temperature.(example - cooling temperature set
on the device: -20°C, hysteresis temperature: +2°C, compressor restart temperature: -18°C)

Settings enabling leveling of differences between the real temperature of the inside of the left
ventricle of the device and the temperature set on the control panel (example - cooling
temperature of the left ventricle of the device: 0°C, actual temperature inside the ventricle:
-5°C,

 

temperature to be set to level the diffe5°C)

Setting delaying / accelerating the compressor off after reaching the temperature set on the
left ventricle control panel

Right ventricular hysteresis setting - the compressor will start after exceeding the sum of the
set device temperature and hysteresis temperature

(example - cooling temperature set on the

device: -20°C, hysteresis temperature: +2°C, compressor restart temperature: -18°C)

Settings enabling leveling of differences between the actual temperature of the inside of the
right chamber of the device and the temperature set on the control panel (example - cooling
temperature of the right chamber set on the device: 0°C, actual temperature insidethe
chamber: -5°C, temperature to be set to level the diffe5°C)

Setting delaying / accelerating the compressor off after reaching the temperature set on the
right ventricle control panel

6°C

2°C

L-Box  

1°C

R-Box  

2°C

°C

H                             M                            L

MAX                                                     ECO

BACK

SENIOR  SE T TING

Smart  Car  Fridge

Max  Temperature

Min  Temperature

Start  Delay

Le   Hysteresis

Right  Hysteresis

Le   TC:  T≥-6°C

Right  TC:  T≥-6°C

Le   TC:  12≤T˂-6°C

Right  TC:  12≤T˂-6°C

RESET

UNBIND

Le   TC:  T<-12°C

Right  TC:  T<-12°C

Le   TC:  Shutdown

Right  TC:  Shutdown

ON

20°C

-20°C

0M

2°C

2°C

0°C

0°C

0°C

0°C

-4°C

-4°C

0°C

0°C

Current temperature inside the 

left

 chamber 

Current temperature inside the right chamber 

 

Button

 for changing the target temperature inside the 

left

 ventricle

 

Button

 for changing the target temperature inside the 

right

 ventricle

Settings change button

Return to the previous screen

 

Battery protection

 

mode change 

slider

 (H / M / L)

Cooling mode

 

change 

slider

 (MAX / ECO)

Summary of Contents for TX95B

Page 1: ...TX95B USER MANUAL PORTABLE FRIDGE WITH COMPRESSOR Instrukcja obs ugi w wersji elektronicznej Digital version of the user manual Digitale Version der Bedienungsanleitung...

Page 2: ...ion appliance is not intended to be used as a built in appliance This appliance is intended to be used in household and similar applications such as Sta kitchen areas in shops o ces and other working...

Page 3: ...the manufacturer The use of an incompatible or non original battery may damage the device and void the warranty 15600mAh battery allows you to maintain the temperature inside the device for up to 3 h...

Page 4: ...reinstall the battery slot cover Warning It is prohibited to connect two types of external power source DC AC solar panel to the device This may damage the device When the device is powered by a solar...

Page 5: ...ion M medium protection L low protection Default set to high protection H When connecting the device to the application via Bluetooth Pressing once when the AP message appears on the device control pa...

Page 6: ...rature example cooling temperature set on the device 20 C hysteresis temperature 2 C compressor restart temperature 18 C Settings enabling leveling of di erences between the actual temperature of the...

Page 7: ...at start up The device does not work Check if the device has been switched on with the button Check that the device is correctly connected to the power source Check whether the power supply is functi...

Page 8: ...e Chiny Model identifier GRT90 145600 Input voltage 100 240V Input AC frequency 50 60Hz Output voltage 14 5V Output current 6 0A Output power 87W Average active efficiency 90 Efficiency at low load 10...

Reviews: