OPERATION
PSI
MPA
UNIT
STEPS
MODEI3
12
11
10
17
14 FLOW
o
CUT-65DS
UNIT
Press this button to change the gas pressure display values from PSI to MPA or from MPA to PSI.
GAS
PRESSURE
DISPLAY
This display shows the gas pressure in PSI or MPA Unit.
When certain system faults occur, this display shows a fault code See error codes and solutions on page 25
PSVMPI
Gas pressure unit
CENTER
KNOB
Adjustment of the electric current value and POST Flow time value by turning the center knob left or right
1 IOW220V
This display shows the input voltage (110/220VAC)
POWER ON LED (Green)
When illuminated, this LED indicates that the power switch is set to ON and the system is ready to cut
LED (Yellow)
Yellow light on: the input voltage
is over or below the reasonable
range. The cutting effect will be worse. Need to
check whether the input voltage is normal.
WARNING
When the internal components
Of the cutter are damaged, the WARNING indicator lights up
Display the current cutting mode is 2T/4T.
THERMOMETER
ICON
When the operating temperature
Of the machine is too high, the gas pressure display shows E-3. Thermal protection
(the thermometer
symbol lights up).
STEPS
MODE
Press this button to toggle between 2T and 4T.
POST
FLOW
Press
this
button
to enter
the
set
Post
flow
time
mode.
Setting output current mode indicator, the indicator light is on when the machine is in setting current mode
CURRENT
VALUE
AND
POST
FLOW
TIME
DISPLAY
This display shows the set output current or set post flow time.
Post flow time setting mode indicator, the indicator lights up when the machine is in post flow time setting mode.
(Post flow-After you complete a cut and release the torch trigger, air continues to flow from the torch in order to cool
the consumables.)
-15