![Yenen LPG Flow Meter Installation And Operation Manual Download Page 18](http://html1.mh-extra.com/html/yenen/lpg-flow-meter/lpg-flow-meter_installation-and-operation-manual_3277437018.webp)
Page 18 / 19
26.12.2011
LFM-02-e
Rev Nr: 7
Appendix B
– Torque table
Dimension
Location
Torque
(kgf-m)
Tool
M6 Bolt (8.8)*
Adjustment cover
1.42
10 metric wrench
M6 Bolt (8.8)*
Magnetic flange, upper body,
lower cover
3.36
13 metric wrench
M10 Bolt (8.8)*
Side covers and adjustment side
cover
6.72
17 metric wrench
M10 Nut
Piston arms
6.72
17 metric wrench
1/4
” NPT plug
Upper body
3
6 allen wrench
1/4
” NPT connections
Hydraulic connectors
Solenoid valves
Purge valves
Check valve
Manometer
Safety relief valve
Common connections on the
hydraulic set.
3
17-19 metric
wrench
3/4” NPT connections
Hydraulic connectors
Break Away
Access Flow Valve
Nozzle
Differential Valve
PN40 Ball Valve
Common connections on the
hydraulic set.
11.5
32-36 metric
wrench
1” Rp connection
Yenen inlet check valve for
flow meter
Inlet of the flow meter
13.5
50 metric wrench
M12 (8.8)*
Yenen inlet check valve to gas
seperator.
8.66
19 metric wrench
* Quality specification to EN 20898-2
For tightness, apply 2
– 3 drops of Loxeal – Italy 58.11 (or equivalent suitable for LPG) directly on
male threaded connections prior to fastening.