background image

 

liquid. Do not allow refrigerants to come in 
contact with open flame. Refrigerant decom-
position in flame can result in the formation 
of hydrofluoric acid or phosgene gas. Always 
wear safety goggles and gloves. Personal 
protective equipment should be worn to pro-
tect operator from frostbite.

 

8)

Use caution when connecting or discon-
necting. 

Improper usage may result in

refrigerant burns (frostbite). If a major leak
occurs, proceed immediately to a well
ventilated area.

9)

Disconnect recovery machine from
power before servicing. 

An electrical

shock hazard is present when the unit is
disassembled.

10) Repair damaged parts.

 Do not operate

the 

YJ-LTE 

if there is a defective part.

Repair the unit to proper operating condi-
tions before further use.

11) Use recommended accessories.

 Follow

the instructions that accompany all acces-
sories. Improper use may damage equip-

ment or create a hazard.

 

12) Use the 

YJ-LTE 

only with the proper

refrigerants

. (See specifications for a

complete list of compatible refrigerants.)

13)

Operate the 

YJ-LTE 

within the design

parameters only. 

The

 YJ-LTE 

was de-

signed to operate within a temperature
range of 

40

(4

C)

 to 

120

o

F (49

o

C). 

 Do

not operate in a wet location.

14) This machine is not to be used in the pres-

ence of rain or other precipitation.

Caution: 

All refrigerant hoses, recovery tanks,   

refrigerant lines, other vessels containing refrig-
erants and the 

YJ-LTE 

should be handled as if 

under high pressure. When opening a tank con-
taining refrigerant, open valves slowly to pre-
vent release of  refrigerant, especially if the 
valves might be damaged. 
To prevent the risk of fire DO NOT use an 
extension cord longer than 50’ (15 m) and a 
minimum of 16 AWG (1.276 mm

2

), 3 conduc-

tor grounded. 

Direct Liquid/Vapor Recovery 

Refer to the following instructions and the 
diagram below: 
1. Know the type and quantity of  refrigerant

present before servicing any system.

2. Turn off power to the system being ser-

viced.

3. Connect your manifold to the system being

serviced. High side to liquid port and low
side to vapor port as shown in diagram.

4. NOTE – For best performance, use mini-

mum length and maximum diameter
hose(s) between the YJ-LTE recovery
machine and the system. The recovery
hose at the system vapor port connection
must also have a depressor for final system
purge.  In addition, using a low loss hose
for this connection will minimize the
amount of air drawn in during the purge
process.

Summary of Contents for YJ-LTE 95730

Page 1: ...covery System Operation and Maintenance Manual English and Spanish French and German available at www yellowjacket com 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431...

Page 2: ...in well ventilated areas Use the YJ LTE only in locations where mechanical ventilation which provides at least four air changes per hour is present or place the unit 18 above the floor during use The...

Page 3: ...n a temperature range of 40o 4o C to 120o F 49o C Do not operate in a wet location 14 This machine is not to be used in the pres ence of rain or other precipitation Caution All refrigerant hoses recov...

Page 4: ...ng recovery When liquid is no longer visible stop recovery and finish re covering using the Liquid Vapor Recovery process For complete recovery the system must be pulled into a vacuum as required by E...

Page 5: ...y tank as shown in the diagram to the left 3 Purge all hoses of non condensables before recovering refrigerant into recovery cylin der 4 Open valves on the recovery tank 5 Turn the selector valve to P...

Page 6: ...n the speed of the recovery process will be obtained if a heat gun is used specifically to any spots where liquid may have accumulated 4 If recovering large amounts of refrigerant 20 lbs or more the p...

Page 7: ...a particular recovery rate R 12 R 114 R 401A R401B R 401C R 402A R 402B R 404A R 406A R 407A R 407B R 407D R 408A R 409A R 411A R 411B R 412A R 500 R 502 R 507A and R509A Model 95730 95732 95733 9573...

Page 8: ...lt in a denial of the over the counter exchange The following exceptions will not be covered under this warranty Recovery products that have been altered misused or improperly maintained The following...

Reviews: