background image

 

 

RecoverXLT

®

 Oil-Less Universal 

Refrigerant Recovery System 

PN 151204 RevB 

 

Operation and Maintenance           

Manual for 95760 and 95762 

 

(For serial numbers 

22120038

 and higher)

 

 

English, Spanish, French and German manuals available at: 

https://yellowjacket.com/product/recover-xlt/ 

Summary of Contents for RecoverXLT

Page 1: ...efrigerant Recovery System PN 151204 RevB Operation and Maintenance Manual for 95760 and 95762 For serial numbers 22120038 and higher English Spanish French and German manuals available at https yello...

Page 2: ...h provides at least four air changes per hour is present or place the unit 18 above the floor during use The RecoverXLT should not be used near open containers of gasoline or any other flammable liqui...

Page 3: ...read an increase in suction pressure indicating the refrigerant that was trapped in the machine 2 Wait until the Low Pressure Switch again stops the unit at the appropriate vacuum 3 Close the valve o...

Page 4: ...1 4 DISCHARGE port of the RecoverXLT Note Be sure to connect hose ends with shut off to suction and discharge ports of recovery machine for best performance use 3 8 hoses 6 Purge all hoses of non cond...

Page 5: ...e pulled into a vacuum as required by EPA standards This process requires the following equipment 1 An extra hose for the push pull recovery 2 A recovery cylinder with about 5 lbs of refrigerant 3 A s...

Page 6: ...ns there is already liquid in the tank and over filling can be a concern Over filling a recovery cylinder can have disastrous results 3 Refrigerant responds to heat Therefore a significant increase in...

Page 7: ...Tighten hose connections Compressor seals are worn Rebuild compressor replace piston seal Hoses are not tight Tighten hoses Leak in HVAC R system Find and repair leak in system Unit running sluggish...

Page 8: ...s 8 Compressor 1 25 HP 2 Cylinder Oil less Reciprocating Air Cooled Power Source 100 240VAC 1ph 50 60Hz Amperage 14 0 amps Motor Type Variable Speed Brushless DC 1200 3000 RPM Size Height 12 50 Width...

Page 9: ...ocker Switch 95451 Gauge High 95217 Rubber Feet 95452 Gauge Low 95444 Case Front 95453 Manifold Assembly 95445 Case Back 95515 Discharge Port 95446 Case Half 95522 Suction Port 95447 Cord Wrap 95563 C...

Page 10: ...ed or improperly maintained The following must be done before returning unit 1 Call our technical service personnel at 800 769 8370 to assess if the problem can be resolved over the phone 2 Obtain an...

Reviews: