background image

 

 

 

10

 

YELLOW JACKET

®

 Products Division

 

Ritchie Engineering Co., Inc.

 

10950 Hampshire Avenue South

 

Bloomington, MN 55438

 

e

-

mail: [email protected]

 

www.yellowjacket.com

 

Phone: 800

-

769

-

8370

 

Int’l Phone: 952

-

943

-

1333

 

Fax: 800

-

322

-

8684

 

Int’l Fax: 952

-

943

-

1605

 

 

Printed in U.S.A.

 

WARRANTY INFORMATION 

Ritchie Engineering Company, Inc. guarantees 

YELLOW JACKET

® 

products to be free of 

defective material and workmanship which could 

affect the life of the product when used for the 

purpose for which it was designed. Warranty does 

not cover items that have been altered, abused or 

returned solely in need of field service mainte-

nance. 

 

 

YELLOW JACKET

®

 recovery products (UPC 

957xx) are covered by a one year warranty for 

parts and labor. The 115V recovery products 

(UPC 95760 and 95762) have an extended three 

year compressor warranty. The warranty also 

allows for a one year over

-

the

-

counter exchange, 

when applicable. To receive this over

-

the

-

counter 

exchange, call Ritchie Engineering Customer 

Service at (800) 769

-

8370 and get the required 

authorization number. Failure to get the required 

authorization number could result in a denial of 

the over

-

the

-

counter exchange.

 

 

The following exceptions will not be covered 

under this warranty: Recovery products that have 

been altered, misused, or improperly maintained.

 

 

The following must be done before returning 

unit:

 

1)

 

Call our technical service personnel at      

(800) 769

-

8370 to assess if the problem can  

be resolved over the phone.

 

2)

 

Obtain an SRO number from Ritchie       

Engineering Company, Inc. for the return of 

the product.

 

3)

 

Fax a copy of the original invoice to         

(800) 322

-

8684.

 

Check for damage immediately

.  Prior to     

shipment, all YELLOW JACKET

®

 

RecoverXLT

®

 

Refrigerant Recovery Systems are completely 

tested and inspected to assure compliance with 

Ritchie Engineering factory specifications.

 

If the recovery system carton is damaged, check 

contents immediately. Note damage on shipper’s 

Bill of Lading and have shipper sign statement. 

Notify carrier immediately of the damage to   

arrange inspection of the recovery system and 

packaging. The CARRIER ALONE is responsible 

for handling and settling your claim. Ritchie    

Engineering Company, Inc. will cooperate in  

assessing damage if the recovery system is re-

turned to the factory prepaid.

 

Carton contents include:

 

 

RecoverXLT

®

 Refrigerant Recovery System

 

 

Owner’s manual

 

 

To validate warranty, mail registration card 

within 10 days.

 

IMPORTANT NOTICE TO PURCHASER 

Note: All units must be shipped to the      

Bloomington, MN plant for repair.  

If at any 

time after the warranty period you have problems 

with your YELLOW JACKET

®

 recovery unit, call 

our technical service department for help in    

selecting the correct replacement parts, or to   

arrange for its repair at reasonable costs.

 

Summary of Contents for RecoverXLT

Page 1: ...efrigerant Recovery System PN 151204 RevB Operation and Maintenance Manual for 95760 and 95762 For serial numbers 22120038 and higher English Spanish French and German manuals available at https yello...

Page 2: ...h provides at least four air changes per hour is present or place the unit 18 above the floor during use The RecoverXLT should not be used near open containers of gasoline or any other flammable liqui...

Page 3: ...read an increase in suction pressure indicating the refrigerant that was trapped in the machine 2 Wait until the Low Pressure Switch again stops the unit at the appropriate vacuum 3 Close the valve o...

Page 4: ...1 4 DISCHARGE port of the RecoverXLT Note Be sure to connect hose ends with shut off to suction and discharge ports of recovery machine for best performance use 3 8 hoses 6 Purge all hoses of non cond...

Page 5: ...e pulled into a vacuum as required by EPA standards This process requires the following equipment 1 An extra hose for the push pull recovery 2 A recovery cylinder with about 5 lbs of refrigerant 3 A s...

Page 6: ...ns there is already liquid in the tank and over filling can be a concern Over filling a recovery cylinder can have disastrous results 3 Refrigerant responds to heat Therefore a significant increase in...

Page 7: ...Tighten hose connections Compressor seals are worn Rebuild compressor replace piston seal Hoses are not tight Tighten hoses Leak in HVAC R system Find and repair leak in system Unit running sluggish...

Page 8: ...s 8 Compressor 1 25 HP 2 Cylinder Oil less Reciprocating Air Cooled Power Source 100 240VAC 1ph 50 60Hz Amperage 14 0 amps Motor Type Variable Speed Brushless DC 1200 3000 RPM Size Height 12 50 Width...

Page 9: ...ocker Switch 95451 Gauge High 95217 Rubber Feet 95452 Gauge Low 95444 Case Front 95453 Manifold Assembly 95445 Case Back 95515 Discharge Port 95446 Case Half 95522 Suction Port 95447 Cord Wrap 95563 C...

Page 10: ...ed or improperly maintained The following must be done before returning unit 1 Call our technical service personnel at 800 769 8370 to assess if the problem can be resolved over the phone 2 Obtain an...