yellow jacket 3788 Series Operation Manual Download Page 7

7

 

 

Use only new lubricant to replace the amount          
removed during the recycling process. Discard     
used lubricant per applicable federal, state and        
local requirements. 

5.  Verify the message on the LCD reads 

“RECOVERY COMPLETE.”

 

6.  Press the RESET key.  The LCD should read 

“CHECK OIL LEVELS.”

 

7.  Measure the oil in the oil drain bottle. Dispose of 

recovered oil in a proper manner. 

8.  Close the service valves and disconnect the 

high   and low side auto service hoses from the          
automobile. 

Models with the optional refrigerant identifier 
37881/37888 

The unit will display “IDENTIFY REFRIGERANT?” 

To make your selection use the left or right arrow 
keys to toggle from YES to NO. Press the ENTER 
key to make your selection and then press the Start 
key to start the process. If YES is selected the unit 
will begin the refrigerant identification process. 

If the refrigerant does not pass the identification 
process (98% purity) the unit will display the error 

message “ CONTAMINATED” and the screen will 

show the     results of the identification. Press the 
Reset key and follow the instructions on the screen 
and the unit will clear itself automatically. Repeat 
the identification  process to insure the proper 
identification of the refrigerant purity level. 

If the unit fails the second time follow the on screen 
instructions and take the appropriate steps to re-
move the contaminated refrigerant with a separate 
unit for removal of contaminated refrigerant. 

WARNING:  DO NOT RECOVER CONTAMINATED 
REFRIGERANT WITH THIS UNIT. RECOVERING 
CONTAMINATED REFRIGERANT WILL VOID ALL 
WARRANTIES AND MY CAUSE DAMAGE TO OTH-
ER AUTOMOBILES THAT YOU SERVICE IN THE FU-
TURE. 

 

 

 

RECOVER, cont.

 

VACUUM

 

The vacuum function of the 37880 SERIES is de-
signed to remove air/moisture from the automobile 
A/C system by  pulling a deep vacuum. This mode 
is most often used  after completing a repair that 
required opening the A/C system to the atmos-
phere. Moisture in an A/C system can cause erratic 
operation and must be removed before recharging 
the system with refrigerant.  

VACUUM Operational Steps  

NOTE:  If desired, the gauges of the 880 SERIES 
can now be used to aid investigation of an A/C sys-
tem problem. Ensure the automobile A/C system is 
turned off prior to selecting a mode on the ma-
chine. 

1.  Verify the auto air conditioning system is off. 

2.  Select Vacuum option from the main menu.  

3.  Press the ENTER key. 

4.  When the LCD reads 

“SET VACUUM TIME,”

 set 

the vacuum time by using the numeric keypad 
until the desired time is shown. press ENTER to 

accept the vacuum time shown on the LCD.    
Bypass vacuum time by setting time to zero 
(FULL CYCLE MODE only).  Note: We recom-
mend 10-15 minimum vacuum time to ensure 
proper charging. 

5.  When the LCD reads 

“SET VACUUM HOLD 

TIME,”

 set the vacuum hold time by using the 

numeric keypad  until the desired time is shown.  
press ENTER to  accept the vacuum hold time 
shown on the LCD. Vacuum hold time can be 
bypassed if the time is set to zero.  

6. 

The display will now read “INJECT OIL AFTER 
VACUUM”

 YES or NO Press the left or right    

arrows to select YES or NO. 

7.  The LCD will read 

“CONNECT HOSES PRESS     

ENTER TO CONTINUE”

 

8.  Connect the high and low side auto service  

hoses to the respective high and low side ser-
vice ports on the automobile A/C system. Open 
the service hose valves. 

9.  Press START key to begin vacuum operation. 

Summary of Contents for 3788 Series

Page 1: ...Operation Manual 37837 37880 37881 37882 37887 37888 37889 3788X Series includes 37837 P N 380539 RevF...

Page 2: ...Deliberate inhalation of refrigerants is ex tremely dangerous Death can occur without warning Vapors reduce oxygen available for breathing and are heavier than air De composition products are hazardo...

Page 3: ...por form is a potentially hazardous material Please consult the manufacturer s Material Safety Data Sheet for additional information and adhere to the following safety guidelines Avoid breathing high...

Page 4: ...Low Gauge 4 Auto High Side Hose Red 5 Auto Low Side Hose Blue 6 Tank Vapor Hose Red 7 Tank Liquid Hose Blue 8 Oil Drain Bottle 9 Oil Inject Bottle excluded on 37837 37887 and 37888 10 Tool Tray 11 Ma...

Page 5: ...Option 2 Vacuum is used to vacuum air moisture from a system previously opened to the atmosphere This Option will then proceed to recharge the A C system This Option also allows the technician to veri...

Page 6: ...system problem Ensure the automobile A C system is turned off prior to selecting a mode on the machine 3 Connect the high and low side auto service hoses to the respective high and low side ser vice...

Page 7: ...NTIES AND MY CAUSE DAMAGE TO OTH ER AUTOMOBILES THAT YOU SERVICE IN THE FU TURE RECOVER cont VACUUM The vacuum function of the 37880 SERIES is de signed to remove air moisture from the automobile A C...

Page 8: ...X 1 Verify the auto air conditioning system is off 2 Select CHARGE option from the main menu 3 When the LCD reads SET CHARGE AMOUNT set the amount of refrigerant to be charged into the A C system by u...

Page 9: ...he hold time will count down on the LCD and the unit will beep at the end of the hold time If vacuum hold time was set to zero the unit will transition into charge mode 11 Record the final vacuum leve...

Page 10: ...a hybrid A C system can cause serious issues with the electrical system Having too much of the wrong type of oil in a hybrid A C system can conduct the electricity to the outside of the A C compressor...

Page 11: ...follow the instructions on the screen and the unit will clear itself automatically Repeat the identification process to insure the proper identification of the refrigerant purity level If the unit fa...

Page 12: ...nged periodically to ensure the system is working properly A maintenance reminder prompts you when to change your filters All refrigerant must be removed from the old filters before they are removed F...

Page 13: ...d maintenance Check oil level when pump is running When pump is running oil level should be 1 2 to 5 8 up in the sight glass This level is necessary for proper operation This maintenance is best perfo...

Page 14: ...o a 120 Volt outlet Circuit breaker tripped on shop power panel Bad Main Power switch Loose wire Bad Transformer on microprocessor board Plug into outlet Reset circuit breaker If circuit breaker immed...

Page 15: ...SCALE CALIBRATION ERROR 6 TANK EMPTY REFRIGERANT BELOW 5 OF TANK CAPACITY REFILL TANK CHECK SCALE CALIBRATION ERROR 7 NOT ENOUGH REFRIGERANT UNIT IS LOW ON REFRIGERANT 10 LB MIN REFILL TANK ERROR 8 TA...

Page 16: ...ges Series 41 Manifold valves can be reconditioned using replacement seating cylinder 41133 There will be a reconditioning charge for manifolds returned to the factory for repair If found defective we...

Reviews: