Electrical connection
Check electrical connection cables regularly for damage.
Ensure that the connecting cable is not attached to the
mains when you are checking it.
Electrical connecting cables must correspond to the rel
evant VDE and DIN regulations. Only use connecting ca
bles with the code H 07 RN.
The type designation must be printed on the connecting
cable by regulation.
Faulty electrical connecting cables
Insulation damage often occurs at electrical connecting
cables.
Causes include:
• Pinch points when connecting cables are run through
window or door gaps.
• Kinks resulting from incorrect attachment or laying of
the connection cable.
• Cuts resulting from running over the connecting cable.
• Insulation damage resulting from forcefully pulling out
of the wall socket.
• Cracks through aging of insulation.
Such defective electrical connection cables must not be
used as the insulation damage makes them extremely
hazardous.
Three-phase motor 400 V / 50 Hz
Mains voltage 400 V / 50 Hz
Mains voltage and extension cables must be 5lead (3P
+ N + SL (3/N/PE).
Extension cables must have a minimum crosssection of
1.5 mm².
Mains fuse protection is 16 A maximum.
The product meets the requirements of EN 610003
11 and is subject to special connection conditions. This
means that use of the product at any freely selectable
connection point is not allowed.
•
Given unfavorable conditions in the power supply
the product can cause the voltage to fuctuate tem
porarily.
•
The product is intended solely for use at connection
points that
a) do not exceed a maximum permitted supply im
pedance “Z”, or
b) have a continuous currentcarrying capacity of
the mains of at least 100 A per phase.
•
As the user, you are required to ensure, in consulta
tion with your electric power company if necessary,
that the connection point at which you wish to oper
ate the product meets one of the two requirements,
a) or b), named above.