![YDLIDAR X4 User Manual Download Page 9](http://html.mh-extra.com/html/ydlidar/x4/x4_user-manual_908280009.webp)
www.ydlidar.com Copyright 2015-2019 YDLIDAR
9 /
14
Ranging frequency
is used to switch the Lidar's ranging frequency. The X4 supports 4K, 8K, and 9K ranging
frequency switching. Other versions of the Lidar do not support this function, and the click is
invalid. When the Lidar is in the scanning state, you need to click the scanning control again after
switching the ranging frequency.
ANGLE CALIBRATION
During the mechanical assembly of the Lidar, the user may have a deviation in the zero angle.
In this case, the angle calibration function of the client can be used to calibrate according to
actual needs. The specific operations are as follows:
(1)
Unlock calibration function
Click the unlock control
, the system will pop up the login box, the default password is ydlidar.
The effect of these controls
will change after unlocking.
(2)
setting the baseline
Click
and the system will provide a baseline of the appropriate size as a reference for the
adjustment.
(3)
Adjusting the angle
Click
to adjust the angle to the appropriate position.
(4)
save configuration