PRODUCT CHARACTERISTICS
The deep well pump is intended for pumping clean water from the deep bore wells. The pump is not designed to pump polluted
water, mechanically polluted water, and liquids other than water, such as: oils, petrol, solvents, acids, bases, organic substances,
fats, sewage, faecal matter, as well as water contaminated with such substances. The pumped water should also not contain
mechanical impurities or other abrasive particles.
Caution! The pump can be damaged as a result of stopping of the water
fl
ow through the pump!
The correct, reliable, and safe operation of the tool depends on its proper use, therefore:
Read the entire manual before the
fi
rst use of the device and keep it for further reference.
The supplier shall not be liable for any damage resulting from failure to comply with the safety instructions and recommendations
speci
fi
ed in this manual.
ACCESSORIES
The factory package contains a pump and an on/o
ff
switch junction box to which the pump’s power cord should be attached ac-
cording to the instructions given in the following part of this manual. The pump is not equipped with a discharge hose.
TECHNICAL PARAMETERS
Parameter
Unit
Value
Value
Catalogue No.
YT-85300
YT-85301
Rated voltage
[V~]
230
230
Rated frequency
[Hz]
50
50
Rated power
[W]
370
550
Electrical protection class
I
I
IP protection class
IP58
IP58
Maximum capacity
[l/h]
5400
6000
Maximum pumping height
[m]
35
50
Max. submersion depth
[m]
80
80
Max. water temperature
[
o
C]
35
35
Water connector
[‘’]
5/4
5/4
Max. diameter of mech. impurities
[mm]
1.5
1.5
Dimensions (diameter x height)
[mm]
78 x 955
78 x 1154
Net weight
[kg]
10.4
12.4
Switch-on level
[m]
10
10
Switch-o
ff
level
[m]
2
2
Minimum well diameter
[mm]
100
100
Lifting height [m]
Catalogue No.
Catalogue No.
YT-85300
YT-85301
Capacity [l/h]
Capacity [l/h]
0
5400
6000
20
5000
5500
40
4000
4500
60
3000
3500
80
2500
2500
100
2000
2000
120
1500
1500
105
1000
1000
120
-
200
Caution! The maximum pump capacity pertains to pumping clean water. To ensure maximum capacity, a hose with a diameter
corresponding to the water connector’s maximum diameter must be connected to the pump.
Summary of Contents for YT-85300
Page 19: ...19 RUS 8 II...
Page 20: ...20 RUS 30 16 III IV V VI VII VIII...
Page 21: ...21 RUS IP 0 O C I O 0 3...
Page 23: ...23 UA 8 II...
Page 24: ...24 UA 30 16 III IV V VI VII VIII IP...
Page 25: ...25 UA 0 O C I 0 3...
Page 67: ...67 GR 8 II...
Page 68: ...68 GR RCD 30 mA 16A III IV V VI VII VIII...
Page 69: ...69 GR IP 0 C I 0 3 Mpa...
Page 70: ...I N S T R U K C J A O R Y G I N A L N A 70...