13
Measurement memory
The laser distance meter is equipped with a memory saving automatically the results of the twenty last meas-
urements. The first results are deleted and automatically replaced with recent ones. In order to browse the
saved results, it is required to turn the device on and press the measurement memory button. Further press-
ing the button permits to browse the last twenty results of measurements. Along with the results the display
indicated the memory register number, the applied measurement method and the unit of measurement.
Error messages
Error message
Source of the error
Solution
ERR01
The reflected laser beam is too intense Do not direct the laser beam towards a reflective surface. If
required, cover a reflective surface with paper
ERR02
Out of range. The measured distance
does not fall within the range of the
laser distance meter
Carry out a measurement whose results will fall within the
range of the laser distance meter
ERR03
The reflected laser beam is too week
Direct the laser beam towards another object or cover the
object with paper
ERR06
Signal indicating the need to replace
the batteries
Replace the batteries
Troubleshooting
Problem
Cause Solution
The device cannot be turned on
The batteries are incorrectly installed
Install the batteries observing polarity
The batteries are worn out
Install new batteries
The switch button lacks electric contact
Press the switch harder or have the
laser distance meter serviced
The device emits clicks during
measurements
This is the sound of switching the optical path
Normal phenomenon
Error signal is displayed
Check the error code in: „Error messages”
Observe the recommendations
indicated in: „Error messages”