background image

By entering 

Exit

 res. closing the window you may terminate the Telnet connection at any

time.

After establishment of a Telnet connection the Panel PC provides you with commands. A

list of possible commands with a short description is available via the command help. By

beginning with "help" before a command you receive help to this command.

4.7.5  VNC server

The Touch Panel has an integrated VNC server (virtual network control) that allows the

total control of the Touch Panel with a PC via network. For this, a window displays the

current Touch Panel content for remote control. Operation is performed via PC keyboard

and mouse. Condition for the VNC communication is, that the VNC server is started on

the Touch Panel and a VNC client on the PC. You may download a VNC client as free-

ware from internet.

Because you can deactivate all safety attitudes with the VNC server, you

should use these exclusively for start-up! Per default the VNC server is

on delivery deactivated.

Due to software reasons VIPA does not support the VNC server function!

With "Autostart" you can select the automatic startup of the VNC server, via the Startup-

Manager.

Commands

Establishing a VNC con-

nection

VIPA HMI

Deployment under Windows CE 6.0 Prof.

Integrated Server > VNC server

HB160 | TP-ECO | 62K-NHC0 | en | 17-09

 

61

Summary of Contents for VIPA TP-ECO

Page 1: ...TP ECO 62K NHC0 Manual HB160 TP ECO 62K NHC0 en 17 09 VIPA HMI Touch Panel TP610LC www vipa com en service support manual...

Page 2: ...62K NHC0_000_TP610LC 4 EN 2017 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 Email info vipa com Internet www vipa com...

Page 3: ...ger 28 3 5 Connection to a PLC system 31 3 6 Operating system Windows Embedded CE 6 0 Core 31 3 6 1 General 31 3 6 2 Structure 33 3 7 Integrated Server 37 3 7 1 General 37 3 7 2 ftp server 38 3 7 3 VN...

Page 4: ...he EMC equitable assembly of installations 65 5 2 EMC equitable assembly 68 5 3 EMC equitable cabling 69 5 4 Special precautions providing high noise immunity 72 5 5 Checklist for the EMC compliant in...

Page 5: ...ective purchase contract Hereby VIPA GmbH declares that the products and systems are in compliance with the essential requirements and other relevant provisions Conformity is indicated by the CE marki...

Page 6: ...NHC0 DH 01 Windows CE 6 0 Core TP 610LC 62K NHC0 CB 01 Windows CE 6 0 Prof The manual is targeted at users who have a background in automation technology The manual consists of chapters Every chapter...

Page 7: ...onnel in the n project design department n installation department n commissioning n operation CAUTION The following conditions must be met before using or commis sioning the components described in t...

Page 8: ...regulations for handling the respective equipment can prevent failures of electrostatic sensitive modules Modules must be shipped in the original packing material When you are conducting measurements...

Page 9: ...PROFIBUS DP interface optional n Robust aluminium case n Display resolution 1024 x 768 768 x 1024 n Battery backed clock n Resistive analog touch screen n Easy mounting via 10 mounting clips n Protec...

Page 10: ...4 RJ45 jack for Ethernet communication LAN 2 5 RS232 interface COM 1 6 RS232 RS422 RS485 interface COM 2 7 MPI PROFIBUS DP interface COM 3 optional 8 Slot for DC 24V voltage supply 9 Display with tou...

Page 11: ...hernet interfaces cannot be used as a Switch 1 RS232 interface COM 1 2 RS232 RS422 RS485 interface COM 2 3 MPI PROFIBUS DP interface COM 3 optional 4 Slot for DC 24V voltage supply Please make sure th...

Page 12: ...2 3 2 Interfaces VIPA HMI Hardware description Structure Interfaces HB160 TP ECO 62K NHC0 en 17 09 12...

Page 13: ...25 pin SubD female RS232 RS422 RS485 inter face VIPA HMI Hardware description Structure Interfaces HB160 TP ECO 62K NHC0 en 17 09 13...

Page 14: ...these two Ethernet interfaces cannot be used as a Switch Using the Host USB A interface USB mouse keyboard stick or USB hard discs can be connected The Touch Panel has got an integrated power supply...

Page 15: ...f Windows CE this memory is listed as Flashdisk at My Device The connection of USB sticks and USB drives by use of the Host USB A interface is supported by the Touch Panel After connection the storage...

Page 16: ...e degrees of protection are only guaranteed when the following is observed Material thickness at the mounting cut out 2 5 6mm The deviation from the plane for the panel cut out is 0 5mm Permissible su...

Page 17: ...voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental conditions to EN 61131 2 Climatic Storage transport EN 60068 2 14 20 6...

Page 18: ...lses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is necessary 2 6 Technical data 2 6 1 62K NHC0 DH Order no 6...

Page 19: ...or Sub D 9 pin male Serial COM2 RS232 RS422 RS485 COM2 connector Sub D 25 pin female Number of USB A interfaces 1 USB A connector USB A host Number of USB B interfaces USB B connector Number of ethern...

Page 20: ...m Minimum 2 5 mm Maximum front panel thickness 6 mm Weight 3350 g Environmental conditions Operating temperature 0 C to 50 C Storage temperature 20 C to 60 C Certifications UL certification yes KC cer...

Page 21: ...4 h Accuracy max deviation per day 2 s Operating controls Touchscreen resistive Keyboard external via USB Mouse external via USB Interfaces MPI PROFIBUS DP optional MPI PROFIBUS DP connector Serial CO...

Page 22: ...ion type Material aluminum galvanized steel Mounting mounting clips Protect type front side IP 65 Protect type back side IP 20 Dimensions Front panel 325 mm x 263 mm x 6 mm Rear panel 310 mm x 248 mm...

Page 23: ...ation of the panel 4 mounting clips and a small hexagon socket key are required 1 Push the operator panel 3 from the front side into the front panel cutting 1 until it touches the panel with the seal...

Page 24: ...the corresponding ESD packaging 1 Remove the cover plate of the COM3 port by removing the screws and pulling the plate 2 For installation insert the interface module into the opening Push the interfa...

Page 25: ...lation the interface module is automatically recognized and can be configured 1 Remove the screws 2 Push the holding plate from the lugs Use a screwdriver by inserting it gently between the housing an...

Page 26: ...on as the Touch Panel is provided by power supply the VIPA Startup Manager will be loaded At the first startup of the VIPA Startup Manager the following start screen appears n There is a button on the...

Page 27: ...elect image is not suited for your panel an error massage appears If the image is suited for your panel in the following message the current installed image version and the new selected image version...

Page 28: ...Autostart you can select the automatic startup of the VNC server and the Movicon TCP upload server With back you can return to the selection menu The Startup Manager will be closed by Exit and the sys...

Page 29: ...els navigate to your Panel and download the zip file to your PC 4 Unzip the zip file and copy the file to the root directory of your SD card 5 Switch on the panel install the SD card and select via St...

Page 30: ...wait a moment After successful execution the following completion screen appears 9 Confirm this window with OK remove the SD card and re start the panel The panel should start with the Startup Manager...

Page 31: ...icates with the according PLC and reacts to the application courses in the PLC according to the configured processes Via dialogues configured before process values may be monitored graphically altered...

Page 32: ...k on an object opens res executes this n Drag By tapping on an object and then dragging you may move the object on the screen If no object is selected a frame is created by the dragging that selects t...

Page 33: ...like e g applications system settings file browser etc 2 Open applications For every open application a button is to be found in the task bar There is no button for minimizing The switch between the a...

Page 34: ...e implemented At pushed Shift key At pushed a key Please note that can exclusively be entered via the software key board Keyboard At pushed Shift key Software keyboard Keyboard Large KB VIPA HMI Deplo...

Page 35: ...ialog windows for the display properties opens Here you may change the settings for the monitor options For example you may adjust the brightness and contrast via the register Settings n Calibrate tou...

Page 36: ...pyright The register Device Name allows you to change the device name that is e g shown during Ethernet communication n Set the back lighting Via Start Settings Control Panel Power Properties you may...

Page 37: ...client is an application that uses the service of a server within a network For example a web browser is a client because at every call of a website it sends a request to a web server and receives an...

Page 38: ...start the Internet Explorer The settings are saved Below is explained how to establish of a ftp connection between a Windows based PC with Windows Explorer as ftp client and your Touch Panel 1 Connect...

Page 39: ...server is on delivery deactivated Due to software reasons VIPA does not support the VNC server function With Autostart you can select the automatic startup of the VNC server via the Startup Manager Th...

Page 40: ...Touch Panel allows you to access shared resources in a Microsoft network like drives and printer Here you may assign existing public directories or printer in the network to local directories or print...

Page 41: ...tserver archive Username guest Input net use data testserver archiv user guest The connected network drive is then available via network data at the Touch Panel The configuration of a network printer...

Page 42: ...a net use local_name d Example net use data d deletes the network connection to the drive archive of test server Terminate network con nections VIPA HMI Deployment under Windows CE 6 0 Core Access to...

Page 43: ...ation of the panel 4 mounting clips and a small hexagon socket key are required 1 Push the operator panel 3 from the front side into the front panel cutting 1 until it touches the panel with the seal...

Page 44: ...the corresponding ESD packaging 1 Remove the cover plate of the COM3 port by removing the screws and pulling the plate 2 For installation insert the interface module into the opening Push the interfa...

Page 45: ...lation the interface module is automatically recognized and can be configured 1 Remove the screws 2 Push the holding plate from the lugs Use a screwdriver by inserting it gently between the housing an...

Page 46: ...oon as the Touch Panel is provided by power supply the VIPA Startup Manager will be loaded At the first startup of the VIPA Startup Manager the following start screen appears n There is a button on th...

Page 47: ...nd connected storage media These images will be listed with create data and version number Choose your new image If the select image is not suited for your panel an error massage appears If the image...

Page 48: ...y using the buttons and 5 seconds are default n Via Rotation the orientation of the panel can be changed Via Program start with you can add programmes which have to start automatically 1 Select start...

Page 49: ...rtup Manager 4 4 Installation Movicon and Startup Manager After an image update it is necessary to re install Movicon and Startup Manager The cur rent data can be found in the service area of www vipa...

Page 50: ...After start up the following window appears 7 Click Make All the necessary files are copied and the registry is accordingly adjusted The progress is displayed in a new window VIPA HMI Deployment under...

Page 51: ...screen appears 9 Confirm this window with OK remove the SD card and re start the panel The panel should start with the Startup Manager after the restart VIPA HMI Deployment under Windows CE 6 0 Prof...

Page 52: ...icates with the according PLC and reacts to the application courses in the PLC according to the configured processes Via dialogues configured before process values may be monitored graphically altered...

Page 53: ...area at the screen twice A double click on an object opens res executes this n Drag By tapping on an object and then dragging you may move the object on the screen If no object is selected a frame is...

Page 54: ...components of your Touch Panel like e g applications system settings file browser etc 2 Open applications For every open application a button is to be found in the task bar There is no button for min...

Page 55: ...ou to select one of the available software keyboards At the moment the following standard keyboards are implemented At pushed Shift key At pushed a key Please note that can exclusively be entered via...

Page 56: ...rd allows you to enter key entries without connecting an external keyboard As soon as an entry is required the software keyboard is automatically shown Hide Input Panel hides the keyboard again Large...

Page 57: ...ial up Connections The default setting is address assignment via DHCP Please consider with the manual assignment of IP addresses that these are not identical for both interfaces If you accidentally ha...

Page 58: ...iption of the server A client is an application that uses the service of a server within a network For example a web browser is a client because at every call of a website it sends a request to a web...

Page 59: ...start the Internet Explorer The settings are saved Below is explained how to establish of a ftp connection between a Windows based PC with Windows Explorer as ftp client and your Touch Panel 1 Connect...

Page 60: ...ter the following into the address bar IP address webadmin 2 Enter the following into the authentification n User name wince n Password vipatp 4 7 4 Telnet server Telnet is a text based client server...

Page 61: ...Panel content for remote control Operation is performed via PC keyboard and mouse Condition for the VNC communication is that the VNC server is started on the Touch Panel and a VNC client on the PC Y...

Page 62: ...start the VNC client vncviewer exe on your PC 4 Click on Options and deactivate the field Emulate 3 Buttons like shown at Mouse 5 Enter the IP address of the Touch Panel at VNC server Click on OK and...

Page 63: ...ork PC The connection of a local name at the Touch Panel with a shared drive of the network PC happens with the following approach 1 Enter the following in the command prompt net use local_name networ...

Page 64: ...ectory using dir network printer The listing command for all network connections of your Touch Panel is net use You may terminate already assigned network resources via net use local_name d Example ne...

Page 65: ...erent ways n Electromagnetic fields RF coupling n Magnetic fields with power frequency n Bus system n Power supply n Protected earth conductor Depending on the spreading medium lead bound or lead free...

Page 66: ...ie n Sparking lines sparking plugs collector of electric motors welding devices In the most times it is enough to take care of some elementary rules to guarantee the EMC Please regard the following ba...

Page 67: ...ecial EMC actions Consider to wire all inductivities with erase links Please consider luminescent lamps can influence signal lines n Create a homogeneous reference potential and ground all electrical...

Page 68: ...age even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local distant ground constructions cubicles construction and machine parts hav...

Page 69: ...groups Group A Group B Group C Group D Group A 1 2 3 4 Group B 2 1 3 4 Group C 3 3 1 4 Group D 4 4 4 1 1 The lines may be installed in common bundles or cable trusses 2 The lines have to be installed...

Page 70: ...e equipotential bonding conductor must not exceed 10 of the impedance of the screen where screened signal lines are connected between the dif ferent sections of the plant and the screening is connecte...

Page 71: ...e cover Do not connect the screen to PIN 1 of the connector In case of stationary operations it is recommended that the remove the insulation from the screened cable without cutting the screen and to...

Page 72: ...diode using a varistor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wired to the distribution system which is also used to connect the neutral...

Page 73: ...een grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunche...

Reviews: