2.3 Setting Up the
Σ
-Series Servopack
— 2-39 —
Some parameters for speed/torque control and position control have different meanings.
Refer to the list of parameters for each type.
For details of how to set parameters, refer to
3.1.5 Operation in Parameter Setting Mode
.
2.3.2 Jog Speed
Use the following parameter to set or modify a motor speed when operating the
Σ
-Series Ser-
vo from a Digital Operator.
Cn-10
JOGSPD
Jog Speed
Unit:
min
−
1
Setting
Range: 0
to
Maximum
Speed
Factory
Setting:
500
For Speed/Torque
Control and Position
Control
This constant is used to set a motor speed when the motor is operated using a Digital
Operator.
2