9 Option Drive Parameters
44
YASKAWA
TOEP YEACOM 06A V1000 Option PROFINET SI-EP3/V Installation Manual
F6-14
bUS Error Auto Reset
0: Disabled
1: Enabled
0
F7-01 to F7-04 IP Address
Sets static IP address of the SI-EP3/V option when
parameter F7-13=0.
Note:
Parameter F7-01 sets the most significant octet.
192 168 1 20
F7-05 to F7-08 Subnet Mask
Sets static Subnet Mask of network connection.
Note:
Parameter F7-05 sets the most significant octet
255 255 255
0
F7-09 to F7-12 Gateway Address
Sets static Gateway address of network connection.
Note:
Parameter F7-09 sets the most significant octet.
192 168 1 1
F7-13
Address Mode at Startup
Selects how the option address is set.
0: Static
2: DCP
2
F7-14
Duplex Mode Selection
Selects duplex mode setting.
0: Half duplex forced
1: Auto-negotiate duplex mode and communication
speed
2: Full duplex forced
3: Half (port 1)/Auto (port 2)
4: Half (port 1)/Full (port 2)
5: Auto (port 1)/Half (port 2)
6: Auto (port 1)/Full (port 2)
7: Full (port 1)/Half (port 2)
8: Full (port 1)/Auto (port 2)
F7-15
Communication Speed
Selection
Sets the communication speed.
10: 10 Mbps
100: 100 Mbps
101: 10 (port 1)/100 Mbps (port 2)
102: 100 (port 1)/10 Mbps (port 2)
10
F7-16
Communication Loss Timeout
Sets the timeout value for communication loss
detection in tenths of a second.
A value of 0 disables the connection timeout.
Example: An entered value of 100 represents 10.0
seconds.
0.0
F7-23 to F7-27
Option Firmware Version
VST800250
Dynamic Output Assembly
Parameters
Configurable outputs 1 to 5.
If a value other than 0 is assigned to parameters F7-23
to F7-27 and F7-33 to F7-37 by the drive, that value
will take precedent over a value set by the
configuration software. If the value in the drive is 0
(default), the value from the configuration software
will be used.
0
Option Firmware Version
VST800251
Dynamic Output Assembly
Parameters
Configurable outputs 1 to 5.
If a value other than 0 is assigned in the configuration
software, those values will be used, otherwise, the
values of the drive parameters set in parameters F7-23
to F7-27 and F7-33 to F7-37 will be used.
No.
Name
Description
Default