Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5 - 18
Note:
The noise margin of the input signal will decrease if the reference pulse is provided by an
open-collector output. Set parameter Pn200.3 to 1 if the position drifts due to noise.
Selecting a Reference Pulse Form
Use the following parameters to select the reference pulse form used.
The servomotor only rotates at an angle proportional to the input pulse.
Set reference pulse form input to the servo amplifier from the host controller.
Input PULS CN1-7
Reference Pulse Input
Position Control
Input /PULS CN1-8
Reference Pulse Input
Position Control
Input SIGN CN1-11
Reference Code Input
Position Control
Input /SIGN CN1-12
Reference Code Input
Position Control
Parameter
Signal
Setting Range
Control Mode
Pn200.0
Reference Pulse Form
Default Setting: 0
Position Control
Servo Amplifier
+12V
Photocoupler
/PULS
PULS
PL1
Approx.
9mA
Tr1
ON: 1.5V maximum
/SIGN
SIGN
PL2
/CLR
CLR
PL3
P represents twisted pair wires
Host controller
P
P
P
150
Ω
CN1-7
CN1-8
CN1-11
CN1-12
CN1-15
CN1-14
CN1-3
CN1-1
CN1-18
CN1-13
1k
Ω
Servo Amplifier
CN1-7
PULS
Position
reference
pulse
CN1-11
SIGN
Host
controller
Summary of Contents for SGMAH
Page 1: ...Sigma II Series Servo System User s Manual...
Page 2: ......
Page 4: ...ii This page intentionally left blank...
Page 6: ...iv This page intentionally left blank...
Page 10: ...Sigma II User s Manual Table of Contents Preface viii Notes...
Page 17: ...Sigma II User s Manual Table of Contents Preface xv C 6 Torque Control Mode C 9...
Page 18: ...Sigma II User s Manual Table of Contents Preface xvi...
Page 38: ...Sigma II User s Manual Chapter 2 Installation 2 10 NOTES...
Page 472: ...Sigma II User s Manual Appendix C Examples of Standard Connections C 10 Notes...
Page 487: ......