9.7 Autotuning with a Host Reference
9.7.7 Related Parameters
9-40
9.7.7
Related Parameters
The following parameters are automatically adjusted or used as reference when you execute
autotuning with a host reference.
Do not change the settings while autotuning with a host reference is being executed.
Yes: The parameter is automatically set.
No: The parameter is not automatically set, but the setting is read during execution.
Parameter
Name
Automatic Changes
Pn100 (2100h)
Speed Loop Gain
Yes
Pn101 (2101h)
Speed Loop Integral Time Constant
Yes
Pn102 (2102h)
Position Loop Gain
Yes
Pn103 (2103h)
Moment of Inertia Ratio
No
Pn121 (2121h)
Friction Compensation Gain
Yes
Pn123 (2123h)
Friction Compensation Coefficient
Yes
Pn124 (2124h)
Friction Compensation Frequency Correction
No
Pn125 (2125h)
Friction Compensation Gain Correction
Yes
Pn401 (2401h)
First Stage First Torque Reference Filter Time Constant
Yes
Pn408 (2408h)
Torque-Related Function Selections
Yes
Pn409 (2409h)
First Stage Notch Filter Frequency
Yes
Pn40A (240Ah)
First Stage Notch Filter Q Value
Yes
Pn40C (240Ch)
Second Stage Notch Filter Frequency
Yes
Pn40D (240Dh)
Second Stage Notch Filter Q Value
Yes
Pn140 (2140h)
Model Following Control-Related Selections
Yes
Pn141 (2141h)
Model Following Control Gain
Yes
Pn142 (2142h)
Model Following Control Gain Correction
Yes
Pn143 (2143h)
Model Following Control Bias in the Forward Direction
Yes
Pn144 (2144h)
Model Following Control Bias in the Reverse Direction
Yes
Pn145 (2145h)
Vibration Suppression 1 Frequency A
Yes
Pn146 (2146h)
Vibration Suppression 1 Frequency B
Yes
Pn147 (2147h)
Model Following Control Speed Feedforward Compensation
Yes
Pn160 (2160h)
Anti-Resonance Control-Related Selections
Yes
Pn161 (2161h)
Anti-Resonance Frequency
Yes
Pn163 (2163h)
Anti-Resonance Damping Gain
Yes