4.3 Table Parameter Settings for Speed/Torque (Pressure) Table Operation
4.3.1 Setting the Number of Speed Table References and the Number of Torque (Pressure) References
4-4
4.3
Table Parameter Settings for Speed/Torque (Pressure) Table Operation
To perform speed/torque (pressure) table operation, table parameters, such as the speed table
references, speed table switching positions, torque (pressure) references, and torque (pressure)
reference times, must be set in advance.
This section describes the table parameters that must be set.
4.3.1
Setting the Number of Speed Table References and the
Number of Torque (Pressure) References
Set Pn6A4 = n.
X
(Selection of Number of Speed Table References) to the number of
speed table references to use in speed table operation of speed/torque (pressure) operation.
Set Pn6A4 = n.
X
(Selection of Number of Torque (Pressure) References) to the number of
torque (pressure) references to use in torque (pressure) table operation of speed/torque (pres-
sure) table operation.
Parameter
Meaning
When Enabled
Classification
Pn6A4
n.
0
(default setting)
Do not perform speed table operation.
Immediately
Setup
n.
1
Use speed table reference 1 (Pn6AC) for
speed table operation.
n.
2
Use speed table reference 1 (Pn6AC) and
speed table reference 2 (Pn6AE) for speed
table operation.
n.
3
Use speed table reference 1 (Pn6AC) through
speed table reference 3 (Pn6B0) for speed
table operation.
n.
4
Use speed table reference 1 (Pn6AC) through
speed table reference 4 (Pn6B2) for speed
table operation.
n.
5
Use speed table reference 1 (Pn6AC) through
speed table reference 5 (Pn6B4) for speed
table operation.
n.
6
Use speed table reference 1 (Pn6AC) through
speed table reference 6 (Pn6B6) for speed
table operation.
n.
7
Use speed table reference 1 (Pn6AC) through
speed table reference 7 (Pn6B8) for speed
table operation.
n.
8
Use speed table reference 1 (Pn6AC) through
speed table reference 8 (Pn6BA) for speed
table operation.
n.
9
Use speed table reference 1 (Pn6AC) through
speed table reference 9 (Pn6BC) for speed
table operation.
n.
A
Use speed table reference 1 (Pn6AC) through
speed table reference 10 (Pn6BE) for speed
table operation.
n.
0
(default setting)
Do not perform torque (pressure) table opera-
tion.
n.
1
Use torque (pressure) table reference 1
(Pn6D2) for torque (pressure) table operation.
n.
2
Use torque (pressure) table reference 1
(Pn6D2) and torque (pressure) table reference
2 (Pn6D4) for torque (pressure) table opera-
tion.
Continued on next page.
Summary of Contents for SGD7S-R70A20A023F40B
Page 52: ...3 7 Monitoring 3 23...