DOCR-070645-E
Page 94 of 102
6.3 Uninstalling the Inverter
Uninstall the inverter according to the following steps when the service is due or for
other reasons:
1.) Turn off the AC breaker and use Padlocks if provided.
2.) Turn off the DC breaker and use Padlocks if provided.
(Skip this step if there is no DC circuit breaker.)
3.) Switch the AC switch to “OFF” position.
4.) Switch the DC switch to “OFF” position.
5.) Wait for 10 minutes to ensure the internal capacitors have been completely
discharged.
6.) Measure the AC output cable terminal voltage against ground and make sure
the voltage is 0V.
7.) Disconnect the AC and EGC cables referring to “2.3.2 AC and Ground
Connection”.
8.) Disconnect the DC cables referring to “2.3.1 DC Connection”.
9.) Uninstall the inverter using the reverse of its installation steps referring to “2.2
Mechanical Installation”.
7.0: Product Warranty and RMA Policy
The current warranty and RMA statement for the product is available online at
http://www.solectria.com/support/documentation/warranty-information/grid-tied-i
nverter-warranty-letter/
. If you do not have access to the internet or to request a
copy to be mailed to you, please contact our Technical Service department
978-683-9700 x 2.
DANGER:
Please disconnect the electrical connection in strict accordance with the
following steps. Otherwise, the inverter will be damaged and the service
personnel’s life will be endangered.
Veuillez débrancher la connexion électrique en stricte conformité avec
les étapes suivantes. Sinon, l'onduleur sera endommagée et la vie du
personnel de service sera mise en danger.