Figure 2.27- DC Input Cable Connection (standard wiring box)
(c) If you prefer to route all DC cables thru a single hole inside the wiring box
please refer to Figure 2.28
Figure 2.28- DC Input Cable Connection
① Remove the 4 screws on the wiring box and take off the adaptor plate (refer to
Fig.2.22).
② Using a knockout punch tool, create the appropriate hole on the adaptor plate.
Note that for your convenience there are guidelines for a 2”, 2.25” and 3” hole.
③ Attach the board to the wiring box with the screws (4 pcs). Torque to 35 in-lbs.