7 Transfer of Parameter Settings
38
YASKAWA America, Inc.
PL.GA500.01 YASKAWA AC Drive - V1000 to GA500 Transition Guide
0x0568 N8-41
Superimposed
Harmonic Polarity
Estimation
Proportional Gain
Sets the P gain for PI control used to estimate
polarity.
There is usually no need to change.
You set the response of the speed estimation for
high frequency injection. N8-57 (high frequency
superimposed selection) is valid at the time of
the 1.
Unit [Hz]
1.0~100.0
-10.00~
10.00
3.0
1.00
DEC Hz
0x0569 N8-42
Integral Time for
Superimposed
Harmonic Polarity
Estimation
Sets the integral time in 0.01 sec units for PI
control used to estimate polarity.
There is usually no need to change.
You set the damping factor of the speed
estimation for high frequency injection. N8-57
(high frequency superimposed selection) is valid
at the time of the 1. Unit is [-]
0.1~5.0
0.00~9.99
1.0
0.01
DEC
0x053E N8-51
Acceleration Time
Pull-In Current*
Sets the pull-in current during acceleration as a
percentage of the motor rated current (E5-03).
Set to a high value when more starting torque is
needed.
0~200
0~200
A1-02
Depend
50
DEC %
0x05C3 N8-74
Light Load Iq
Level
Set n8-48 [Pull-in/Light Load Id Current] to the
level of the load current (q-axis current) to be
applied.
0~255
0.0~250.0
30.0
30.0
DEC %
0x05C4 N8-75
Medium Load Iq
Level (low)
Set n8-78 [Medium Load Id Current] to the level
of the load current (q-axis current) to be applied.
0~255
0.0~250.0
50.0
50.0
DEC %
0x05CE N8-77
Heavy Load Iq
Level
Set n8-49 [Heavy Load Id Current] to the level of
the load current (q-axis current) to be applied.
0~255
0.0~250.0
90.0
90.0
DEC %
0x05F4 N8-78
Medium Load Id
Current
Sets the level of the pull-in current for midrange
loads.
0~255
-200.0~
200.0
0.0
0.0
DEC %
0x0500 O1-01
Drive Mode Unit
Monitor Selection
Sets the U monitor that shows in Drive Mode.
This parameter is only enabled for LED keypads.
104~855
104~813
106
106
DEC
0x0502 O1-03
Digital Operator
Display Selection
Selects the display units for the frequency
reference and output frequency.
0: 0.01 Hz
1: 0.01% (100% = E1-04)
2: r/min
3: User-selected units
0~3
0~3
A1-02
Depend
0
DEC
0x0504 O1-05 LCD Contrast
Sets the contrast of the digital operator LCD. A
setting of "0" is the lightest contrast and a setting
of "10" is the darkest contrast.
5: Normal contrast
0~10
0~5
5
3
DEC
0x164A Q2-11
Drive U1 Monitor
Select 1
Drive U1 Monitor Select 1
0~21
0~3,
6~13
0
0
DEC
0x164B Q2-12
Drive U1 Monitor
Select 2
Drive U1 Monitor Select 2
0~21
0~3,
6~13
0
0
DEC
0x0701 T1-01
Auto-Tuning Mode
Selection
Selects the type of Auto-Tuning to be used.
0: Rotational Auto-Tuning
1: Stationary Auto-Tuning 1
2: StaTun for LinetoLine Resistance
0~2
0,
2~3
0
0
DEC
0x0702 T1-02 Motor Rated Power
Sets the motor rated power in kilowatts (kW).
Note: If motor power is given in horsepower,
power in kW can be calculated using the
following formula: kW = HP x 0.746
0.00~
650.00
0.03~
650.00
0.40
0.40
DEC kW
Reg.
No.
Param.
No.
Name
Description
Setting Range
Initial Setting
Base Unit
GA500
V1000
GA500
V1000