background image

4.6  Security

If only the Administrator's password is set, then this only limits access to setup and is only

asked for when entering setup.

If only the User's password is set, then this is a power on password and must be entered

to boot or enter setup. In Setup the user will have administrator rights.

If ONLY the Administra-

tor's password is set

If ONLY the User's pass-

word is set

VIPA HMI

BIOS setup

Security 

HB160 | PPC | 67S-RRJ0 | en | 20-20

 

55

Summary of Contents for PPC021 EC

Page 1: ...PPC 67S RRJ0 Manual HB160 PPC 67S RRJ0 en 20 20 VIPA HMI Panel PC PPC021 EC...

Page 2: ...67S RRJ0_000_PPC021EC 2 EN 2020 YASKAWA Europe GmbH Ohmstra e 4 91074 Herzogenaurach Tel 49 9132 744 0 Fax 49 9132 744 186 Email info yaskawa eu com Internet www yaskawa eu com...

Page 3: ...Operating system Windows Embedded Compact 7 28 3 5 1 General 28 3 5 2 Structure 29 3 6 Integrated server 31 3 6 1 General 31 3 6 2 ftp server 32 3 6 3 Telnet server 33 3 6 4 VNC server 34 3 7 Access...

Page 4: ...Descriptions may be included for units which are not present at the customer site The exact scope of delivery is described in the respective purchase contract Hereby YASKAWA Europe GmbH declares that...

Page 5: ...l PC 67S RRJ0 It contains a description of the structure project engineering and deployment Product Order number as of state HW FW BS PPC021 EC 67S RRJ0 01 1 0 0 Windows Embedded Compact 7 The manual...

Page 6: ...rsonnel in the n project design department n installation department n commissioning n operation CAUTION The following conditions must be met before using or commis sioning the components described in...

Page 7: ...les that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the consequent implementation of protection devices a...

Page 8: ...P multitouch n Display resolution 1920 x 1080 n Processor Baytrail Intel Celeron J1900 Quad core 2GHz n Work memory 2x 204Pin DDR3 SO DIMM Socket 2GB DDR3 n User memory 2GB SATA DOM n CFast slot n 2 R...

Page 9: ...3 0 7 2x USB A interface USB 2 0 8 RJ45 jack for Ethernet communication LAN 2 9 RJ45 jack for Ethernet communication LAN 1 10 2 pin connector for remote Power switch 11 3 5mm Audio Line out 12 Power...

Page 10: ...11 3 5mm Audio Line out Please make sure that the Panel PC always has to be supplied with external voltage 1 Slot for CFast storage media 2 Power switch pushbutton The Panel PC starts automatically wh...

Page 11: ...d with DC 12 30V For this you find an according DC 24V slot at the back The power supply is protected against inverse polarity and overcurrent VGA SubD HD15 jack to connect a second display Power supp...

Page 12: ...it s RS422 interface n Logical conditions as voltage difference between 2 twisted lines n Serial bus connection full duplex four wire operation n Line length 250m at 115 2kbit s 1200m at 19 2kbit s n...

Page 13: ...VIPA HMI Hardware description Structure Interfaces HB160 PPC 67S RRJ0 en 20 20 13...

Page 14: ...cks provide the interface to the twisted pair cable required for Ethernet LEDs Activity yellow Link green Link orange Description blinks 1000Mbit s link blinks 100Mbit s link blinks 10Mbit s link or n...

Page 15: ...e supported by the Panel PC At the back of the Panel PC there is a card slot for a memory card At this slot you can plug storage modules of the type CFast 2 0 600 MB s 6GBit s SATA protocol not hot sw...

Page 16: ...x H x D 542 x 362 x 54 2mm Installation depth 54 2mm The degrees of protection are only guaranteed when the following is observed The material thickness of the installation cut out is 3 12mm The devia...

Page 17: ...ion voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental conditions to EN 61131 2 Climatic Storage transport EN 60068 2 14 2...

Page 18: ...with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is necessary 2 6 Technical data Order no 67S RRJ0 EB Type Panel P...

Page 19: ...le Serial COM2 RS232 RS422 RS485 COM2 connector Sub D 9 pin male Number of USB A interfaces 3 USB A connector USB A host Number of USB B interfaces USB B connector Number of ethernet interfaces 2 Ethe...

Page 20: ...tection class NEMA front side Protection class NEMA back side Dimensions Front panel 562 4 mm x 382 4 mm x 6 7 mm Rear panel 542 mm x 362 mm x 54 2 mm Installation cut out Width 547 mm Height 367 mm M...

Page 21: ...g tableau and control cabinet fronts the Panel PC requires the following front panel cutting Panel PC W x H in mm 67S RRJ0 547 x 367mm The material thickness of the installation cut out is 3 12mm For...

Page 22: ...ulling the plate 2 With the label facing up insert the CFast card until it is completely seated in the slot and reinstall the cover plate After installation the CFast card is automatically recognized...

Page 23: ...t not be let within the same cable shaft as high voltage cables 3 3 1 Firmware update To execute the firmware update an external keyboard and an USB stick memory size 4GB is necessary The new image fi...

Page 24: ...sword will be requested when interrupting the start countdown By default no password is defined In Settings the system settings can be set exactly like via Windows Start Settings Control Panel n To ex...

Page 25: ...y Time you can adjust a delay time 0 by using the buttons and 5 seconds are default n Via Program start with you can add programmes which have to start automati cally n Via Rotation the orientation of...

Page 26: ...ight the local settings and the LAN settings will be saved by Backup in Flashdisk Backup The name of the backup file is backup bkv Which settings will be saved and the storage location are defined in...

Page 27: ...ed runtime version of the HMI SCADA project engineering platforms your project is run able n By using the according communication driver the Panel PC supports connecting options to the PLC via Etherne...

Page 28: ...wice A double click on an object opens res executes this n Drag By tapping on an object and then dragging you can move the object on the screen If no object is selected a frame is created by the dragg...

Page 29: ...access to all components of your Panel PC such as appli cations system settings file browser etc 2 Open applications For every open application a button can be found in the task bar There is no button...

Page 30: ...ock The software keyboard allows you to enter key entries without connecting an external keyboard As soon as an entry is required the software keyboard is automatically shown Hide Input Panel hides th...

Page 31: ...General The Panel PC has several integrated server that enable a remote maintenance within a network Some servers only allow access by means of entering User name and Pass word The following login dat...

Page 32: ...ry view for ftp sites 2 Restart the Internet Explorer The settings are saved Below is explained how to establish of a ftp connection between a Windows based PC with Windows Explorer as ftp client and...

Page 33: ...llowing into the address bar telnet IP address When the connection is established the Panel PC asks for the user name and the password 2 Enter the following Login wince Password vipatp entry is hidden...

Page 34: ...eactivate all safety attitudes with the VNC server you should use these exclusively for start up For this reason the VNC server is on delivery deactivated Due to software reasons YASKAWA does not supp...

Page 35: ...d vipatp You can change the password over the configuration file for this execute vncconfig exe Now a VNC connection is established and the screen con tent of the Panel PC is monitored within a window...

Page 36: ...ork PC The connection of a local name at the Panel PC with a shared drive of the network PC happens with the following approach 1 Enter the following in the command prompt net use local_name network d...

Page 37: ...Making changes to the power management configuration n Changing the password or making other changes to the security setup Normally CMOS setup is needed when the system hardware is not consistent wit...

Page 38: ...ves and exits the setup program Enter Enters the highlighted submenu When 4 appears on the left of a particular field it indicates that a submenu which contains addi tional options are available for t...

Page 39: ...mat is hour minute second n hour displays hours from 00 to 23 n minute displays minutes from 00 to 59 n second displays seconds from 00 to 59 4 3 Advanced This menu allows you to configure the system...

Page 40: ...This section is used to configure Advanced Configuration and Power Interface ACPI Settings Submenu ACPI Settings VIPA HMI BIOS setup Advanced HB160 PPC 67S RRJ0 en 20 20 40...

Page 41: ...hen the suspend button is pressed Suspend Disabled Sleep state disabled S3 Suspend to RAM Standby mode enabled Windows saves the system state in RAM This section is used to configure serial ports Enab...

Page 42: ...splays the Super I O Chip used on the board This section is used to configure serial port 1 Super IO Chip Submenu Serial Port 1 Configuration VIPA HMI BIOS setup Advanced HB160 PPC 67S RRJ0 en 20 20 4...

Page 43: ...esistor Disabled Terminal resistor not activated Enabled default Terminal resistor activated This section is used to configure serial port 2 Enables or disables the serial port Disabled Serial port is...

Page 44: ...minal resistor not activated Enabled default Terminal resistor activated This section Pc Health Status is used to configure the hardware temperature and vol tages This section is used to configure the...

Page 45: ...ctions are supported Enabled Limit the return value to 3 or less than 3 XD can prevent certain classes of malicious buffer overflow attacks Enabled Permit the switching on of the execute disable funct...

Page 46: ...This section is used to configure the Processor Power Management PPM configuration Submenu PPM Configu ration VIPA HMI BIOS setup Advanced HB160 PPC 67S RRJ0 en 20 20 46...

Page 47: ...o use AHCI Advanced Host Con troller Interface AHCI allows the storage driver to enable the advanced serial ATA features which will increase storage performance Enables or disables SATA port 0 Enables...

Page 48: ...ications Enabled Default Enables USB 3 0 controller support Disabled Disables USB 3 0 controller support Enabled Enables XHCI USB 3 0 or EHCI USB 2 0 support Disabled Disables XHCI USB 3 0 or EHCI USB...

Page 49: ...is option only when changing the panel otherwise the display may not work The options are Tact Switch Manual and Light Sensor The default setting is Manual and the Backlight option below will be confi...

Page 50: ...where you left off before power failure occurs Power Off The system s power is off You must press the power button to Power On the system Power On default The system will automatically Power On This s...

Page 51: ...isabled Azalia will be unconditionally disabled Enabled Azalia will be unconditionally enabled Enables or disables internal HDMI Codec for Azalia Audio Controller Azalia HDMI Codec VIPA HMI BIOS setup...

Page 52: ...HCI con troller must always be enabled Enables or disables PCH USB rate matching hubs mode Enables or disables PCH EHCI debug capability Submenu USB Configura tion USB 2 0 EHCI Support USB RMH Mode US...

Page 53: ...Enables or disables the PCI Express ports 0 3 on the chipset Submenu PCI Express Configuration PCI Express Port 0 PCI Express Port 3 VIPA HMI BIOS setup Chipset HB160 PPC 67S RRJ0 en 20 20 53...

Page 54: ...decrease the time needed to boot the system Controls the execution of UEFI and legacy PXE OpROM Enables or disables the boot option for legacy network devices connected to LAN1 or LAN2 Disabled defaul...

Page 55: ...en entering setup If only the User s password is set then this is a power on password and must be entered to boot or enter setup In Setup the user will have administrator rights If ONLY the Administra...

Page 56: ...t 3 characters and should be maximal 20 characters long Select this to reconfigure the user s password Your password must contain at least 3 characters and should be maximal 20 characters long Adminis...

Page 57: ...irm again before exiting The BIOS setup exits and a restart follows To restore the BIOS to default settings select this field then press Enter A dialog box will appear Confirm by selecting Yes To save...

Page 58: ...erent ways n Electromagnetic fields RF coupling n Magnetic fields with power frequency n Bus system n Power supply n Protected earth conductor Depending on the spreading medium lead bound or lead free...

Page 59: ...lkie n Sparking lines sparking plugs collector of electric motors welding devices In the most times it is enough to take care of some elementary rules to guarantee the EMC Please regard the following...

Page 60: ...special EMC actions Consider to wire all inductivities with erase links Please consider luminescent lamps can influence signal lines n Create a homogeneous reference potential and ground all electrica...

Page 61: ...tage even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local distant ground constructions cubicles construction and machine parts ha...

Page 62: ...groups Group A Group B Group C Group D Group A 1 2 3 4 Group B 2 1 3 4 Group C 3 3 1 4 Group D 4 4 4 1 1 The lines may be installed in common bundles or cable trusses 2 The lines have to be installed...

Page 63: ...e of the equipotential bonding conductor must not exceed 10 of the impedance of the screen where screened signal lines are connected between the dif ferent sections of the plant and the screening is c...

Page 64: ...he cover Do not connect the screen to PIN 1 of the connector In case of stationary operations it is recommended that the remove the insulation from the screened cable without cutting the screen and to...

Page 65: ...Z diode using a varistor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wired to the distribution system which is also used to connect the neutra...

Page 66: ...been grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunc...

Page 67: ...Appendix VIPA HMI Appendix HB160 PPC 67S RRJ0 en 20 20 67...

Page 68: ...Content A History of changes 69 VIPA HMI Appendix HB160 PPC 67S RRJ0 en 20 20 68...

Page 69: ...A History of changes Rev Changes 18 25 The manual was created 20 20 CI adjustment was done VIPA HMI History of changes HB160 PPC 67S RRJ0 en 20 20 69...

Reviews: