EMC
Standard
Comment
Emitted interference
EN 61000-6-4
Class A (Industrial area)
Noise immunity
zone B
EN 61000-6-2
Industrial area
EN 61000-4-2
ESD
8kV at air discharge (degree of severity 3),
4kV at contact discharge (degree of severity 2)
EN 61000-4-3
HF field immunity (casing)
80MHz … 1000MHz, 10V/m, 80% AM (1kHz)
1.4GHz ... 2.0GHz, 3V/m, 80% AM (1kHz)
2GHz ... 2.7GHz, 1V/m, 80% AM (1kHz)
EN 61000-4-6
HF conducted
150kHz … 80MHz, 10V, 80% AM (1kHz)
EN 61000-4-4
Burst, degree of severity 3
EN 61000-4-5
Surge, degree of severity 3
1
1) Due to the high-energetic single pulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is
necessary.
2.6 Use in difficult operating conditions
Without additional protective measures, the products must not be used in
locations with difficult operating conditions; e.g. due to:
–
dust generation
–
chemically active substances (corrosive vapors or gases)
–
strong electric or magnetic fields
HMI
Hardware description
Use in difficult operating conditions
HB160 | PPC | 67K-RSL0 | en | 22-20
18
Summary of Contents for PP010 ES
Page 1: ...PPC 67K RSL0 Manual HB160 PPC 67K RSL0 en 22 20 HMI Panel PC PPC010 ES...
Page 13: ...HMI Hardware description Structure Interfaces HB160 PPC 67K RSL0 en 22 20 13...
Page 70: ...Appendix HMI Appendix HB160 PPC 67K RSL0 en 22 20 70...
Page 71: ...Content A History of changes 72 HMI Appendix HB160 PPC 67K RSL0 en 22 20 71...