Interface panel function
Clearing the status of signals
Page 36
Revised: 07-04-24
MRS6036EN-ch6.fm
!
Status of general output signals at power supply ON
By setting parameter S2C187, it allows to set the status of general output signals (#10010 to
#11287) at the time of when turning the power supply ON. For the parameter setting, refer to
the table below.
!
Status of auxiliary relay signals at power supply ON
By setting parameters from S4C040 to S4C055, it allows to set the status of auxiliary relay
signals (#70010 to #79997) at the time of when turning the power supply ON. For the para-
meter settings, refer to the table below.
Parameters
General output signals
Set values
Explanation
S2C187
#10010 to #11287
0: Hold,
1: Clear
When S2C187 is set to "1", the status of
general output signals will be cleared at
the time of power supply ON.
(All signals are to be set together.)
Parameters
Auxiliary relay signals
Set values
Explanation
S4C040
#70010 to #70647
(Bit specification)
0: Clear,
1: Hold
When a bit specification is set to "1",
the status of auxiliary relay signals
will be held at the time of power
supply ON.
(Bit specification is to be set by a
series of 32 signals.)
S4C041
#70650 to #71287
S4C042
#71290 to #71927
S4C043
#71930 to #72567
S4C044
#72570 to #73207
S4C045
#73210 to #73847
S4C046
#73850 to #74487
S4C047
#74490 to #75127
S4C048
#75130 to #75767
S4C049
#75770 to #76407
S4C050
#76410 to #77047
S4C051
#77050 to #77687
S4C052
#77690 to #78327
S4C053
#78330 to #78967
S4C054
#78970 to #79607
S4C055
#79610 to #79997
Summary of Contents for MOTOMAN-NX100
Page 4: ...Interface panel function Page 4 Revised 07 04 24 MRS6036EN 0 UTOC fm...
Page 6: ...Interface panel function Page 6 Revised 07 04 24 MRS6036EN ch1 fm...
Page 12: ...Interface panel function Interface panel display Page 12 Revised 07 04 24 MRS6036EN ch2 fm...
Page 30: ...Interface panel function Page 30 Revised 07 04 24 MRS6036EN ch4 fm...
Page 34: ...Interface panel function Page 34 Revised 07 04 24 MRS6036EN ch5 fm...
Page 39: ...Notes...