Basic Specifications
5.6 Alterable Operating Range
5-12
167109-1CD
HW1482308
MS165
5.6.3 Adjustment to the Pulse Limitation of S-Axis
Apply the Instruction for
“DX200 INSTRUCTIONS chapter 8.17 Changing
the Parameter Setting (manual No. RE-CTO-A220)”
as a part of reference
materials for adjusting the programming pendant when modifying the
range of motion of S-Axis.
The limitation to the pulse (Pulse Soft Limit + 1st Axis) : SICxG400
The limitation to the pulse (Pulse Soft Limit - 1st Axis) : SICxG408
* Refer to
chapter 5.6 “Alterable Operating Range”
Degree
0
15
30
45
60
75
90
Number of
Pulse
0
28672
57344
86016
114688
143360
172032
Degree
105
120
135
150
165
180
Number of
Pulse
200704
229376
258048
286720
315392
344064
NOTE
Adjust both of the pulse limitation and the angle of S-Axis
mechanical stopper as modifying the range of motion for
machinery.
41 of 100