8-3
158813-1CD
HW1480080
MH80 Manipulator
8 Electrical Equipment Specification
8.1 Position of Limit Switch
8.1.3.3 Setting Range of LU-Axes Interference Angle
L- and U-axes interference limit switches are designed to check the
interference angle of L- and U-axes.
As shown in
Fig. 8-3 “LU-Axes Interference Angle”
, the operation range of
U-axis can be set to any angles 9° to +297° as the interference
angle with L-axis.
Fig. 8-3: LU-Axes Interference Angle
39 of 77