5.5 Alterable Operating Range
5-7
HW0482143
5.5.3
Adjustment to the Pulse Limitation of S-Axis
Apply the Instruction for NX100 Concurrent I/O Parameter (Manual No. RE-CKI-A442) as
part of reference materials for adjusting the programming pendant when modifying the range
of motion of S-Axis.
The limitation to the pulse (Pulse Soft Limit
+ 1st Axis ) : SICxG200
The limitation to the pulse (Pulse Soft Limit
- 1st Axis ) : SICxG208
* Refer to 5.5(p5-4).
Degree
±
0
°
∗ ±
15
°
±
30
°
±
45
°
±
60
°
±
75
°
±
90
°
Number
of Pulse
±
0
±
35109
±
70217
±
105326
±
140434
±
175543
±
210651
Degree
±
105
°
±
120
°
±
135
°
±
150
°
∗ ±
165
°
±
180
°
(Standard)
Number
of Pulse
±
245760
±
280869
±
315977
±
351086
±
386194
±
421303
Adjust both of the pulse limitation and the angle of S-axis mechanical stopper as
modifying the range of motion for machinery.
NOTE
28/71