DX200 Standard Setup
6 Troubleshooting
6.1 Possible Failures at Preparation of the CF
6
Troubleshooting
This section describes the causes and remedies of the possible failures
that are assumed to occur during setup.
6.1
Possible Failures at Preparation of the CF
These failures may occur during the following operations.
Failure 1: The selected drives for “mk_vx_cf” tool are not “E:” to “K:”.
Section 2.1 “Preparing the CF for YCP21”
Section 3.1 “Preparing the CF/USB for Upgrading”
No.
Cause
Remedy
1
The USB hub power
supply is not turned ON.
Connect the AC adapter to the USB hub
and insert the AC adapter into the 100-V
power supply.
2
The USB hub is not
connected to the USB port
of the personal computer.
Connect the USB hub to the USB port of
the personal computer.
3
The USB hub is not
connected to the CF
reader/writer.
Connect the USB hub to the CF reader/
writer.
4
The CD drive is not set to
an appropriate drive (K).
Take above remedies 1 to 3, and then
restart the personal computer.
The “E:” drive is
not displayed.
“Not Use” is
displayed.