5 Installation Procedure
YASKAWA ELECTRIC
TOBP C730600 63C V1000 Option SI-ET3/V Installation Manual
19
2.
The remaining installation steps differ based on drive model. Find the drive model
number on the drive nameplate and refer to the step indicated in
based on
your model number.
Table 5 Installation Steps Based on Drive Model
3.
For IP20/Open-Chassis models CIMR-V
A
B, remove the bottom cover
of the drive by applying pressure to the tabs on each side of the bottom cover. Pull
the bottom cover away from the drive while pushing in on the tabs to release the
cover from the drive. Refer to
for details.
Refer to
BA0006B to BA0018B, 2A0008B to
2A0069B, and 4A0001B to 4A0038B, which require removing the terminal cover
prior to removing the bottom cover.
Figure 6
Figure 6 Remove the Bottom Cover on an IP20/Open-Chassis Drive
(Models CIMR-V
BA0001B to BA0003B and 2A0001B to 2A0006B)
Figure 7
Figure 7 Remove the Terminal Cover and Bottom Cover on an IP20/Open-Chassis Drive
(Models CIMR-V
BA0006B to BA0018B; 2A0008B to 2A0069B; 4A0001B to 4A0038B)
Enclosure Type
<1> Installing the option on an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while maintaining
IP20 conformity.
Drive Model
Proceed to Step
Page
IP20/Open-Chassis
CIMR-V
A
B
IP20/NEMA Type 1
CIMR-V
A
F
V1000
Bottom Cover
Terminal Cover
V1000
GEM_M-III_IM_E_conditional.fm 19 ページ 2017年7月7日 金曜日 午後5時9分