GPD315/V7 Modbus RTU Technical Manual TM 4325
Page
25
Table 5-4 Drive Parameters (continued)
Parameter
ADDR
Name
Set
Description
Default
n038
0126h
Motor Overload
Protection Time
Constant
1 - 60 Minutes
8
0
Operates Only When Drive Is Running
n039
0127h
Cooling Fan
Operation
1
Operates With Power Is ON
0
n040-n049
0128h -
0131h
Reserved
3
1
Run Forward
(2 Wire Sequence)
2
Run Reverse
(2 Wire Sequence)
3
External Fault
(N.O. Contact)
4
External Fault
(N.C. Contact)
5
Fault Reset
6
Multi-Speed Reference 1
7
Multi-Speed Reference 2
8
Multi-Speed Reference 3
9
Multi-Speed Reference 4
10
Jog Reference
11
Accel/Decel Time Switch Command
12
External Baseblock
(N.O. Contact)
13
External Baseblock
(N.C. Contact)
14
Speed Search From Max. Output Frequency
15
Speed Search From Set Frequency
16
Accel/Decel Hold
17
Local/Remote Switch
18
Serial/Terminal Control Switch
19
Emergency Stop Fault
(N.O. Contact)
(Stop Method n005)
20
Emergency Stop Alarm
(N.O. Contact)
(Stop Method n005)
21
Emergency Stop Fault
(N.C. Contact)
(Stop Method n005)
22
Emergency Stop Alarm
(N.C. Contact)
(Stop Method n005)
23
PID Cancel
24
PID Integral Reset
25
PID Integral Hold
n050
0132h
Multi-Function
Input 1
Terminal S1
26 - 33 Reserved
3
1
n051
0133h
Multi-Function
Input 2
Terminal S2
Same As Parameter n050
2
0
Forward/Reverse
7
n052
0134h
Multi-Function
Input 3
Terminal S3
1 - 25
Others same as parameter n050
3
n053
0135h
Multi-Function
Input 4
Terminal S4
Same As Parameter n050
5
n054
0136h
Multi-Function
Input 5
Terminal S5
Same As Parameter n050
6
n055
0137h
Multi-Function
Input 6
Terminal S6
Same As Parameter n050
7
1 – 25 Same as parameter n050
34
Up/Down command
8
n056
0138h
Multi-Function
Input 7
Terminal S7
35
Self-Test
10