10.21 Defaults by Drive Model and Duty Rating ND/HD
642
YASKAWA ELECTRIC
SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
No.
Name
Unit
Default
-
Drive
Model
-
4168
4208
4250
4296
C6-01
Normal /
Heavy
Duty
Selection
-
HD1
ND1
HD1
ND1
HD1
ND1
HD1
ND1
0
1
0
1
0
1
0
1
o2-04
Drive
Model
(KVA)
Selection
Hex.
A5
A6
A7
A8
E2-11
(E4-11)
Motor
Rated
Power
(kW)
kW
75
90
90
110
110
132
132
160
L2-02
Power
Loss Ride
Through
Time
s
2
2
2
2
2
2
2
2
L2-03
Minimum
Baseblock
Time
s
1.3
1.5
1.5
1.7
1.7
1.7
1.7
1.8
L2-04
Powerloss
V/f
Recovery
Ramp
Time
s
1
1
1
1
1
1
1
1
L2-05
Undervolt
age
Detection
Lvl (Uv1)
-
380
380
380
380
380
380
380
380
L3-24
Motor
Accel
Time @
Rated
Torque
s
0.533
0.592
0.592
0.646
0.646
0.673
0.673
0.777
L8-02
Overheat
Alarm
Level
°C
110
110
105
105
120
120
120
120
L8-09
Output
Ground
Fault
Detection
-
1
1
1
1
1
1
1
1
L8-38
Carrier
Frequency
Reduction
-
2
2
2
2
2
2
2
2
n1-01
Hunting
Prevention
Selection
-
2
2
2
2
2
2
2
2
n1-03
Hunting
Prevention
Time
Constant
ms
30
30
30
30
30
30
30
30
n1-16
Hunting
Prevention
High Fc
Gain
-
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
n5-02
Motor
Inertia
Accelera
tion Time
s
0.533
0.592
0.592
0.646
0.646
0.673
0.673
0.777
n8-11
Observer
Calculation
Gain 2
-
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
*1