2 Setting
2.2 Setting for the Conveyor Synchronization Operation
2-6
174512-1CD
HW1483164
Conveyor Coordinated
Function
2.2.2 Conveyor Home Position Signal (LS Signal)
Conveyor home position signal (LS signal) for the conveyor specified as
the conveyor coordinated axis can be turned ON by inputing the specific
input.
Create the job and ladder so that the specific input is turned ON at the
timing when the conveyor coordinated axis moves to the home position.
(Refer to
.)
Also, conveyor home position signal for the external conveyor can be
turned ON by the specific input.
(Instead of using the specific input, the external LS signal can be also
used as usual.)
40660
40661
40662
Conveyor
Conveyor
Conveyor
Home position signal
Home position signal
Home position signal
S1
S2
S3
40670
40671
40672
40673
40674
40675
Conveyor
Conveyor
Conveyor
Conveyor
Conveyor
Conveyor
Home
position
signal
Home
position
signal
Home
position
signal
Home
position
signal
Home
position
signal
Home
position
signal
CN1
CN2
CN3
CN4
CN5
CN6
20 of 28