3.2 Operating Procedures for Utility Functions
3.2.12 Adjust Analog Monitor Output Gain (Fn00D)
3-31
3
Utility Function
s
3.2.12
Adjust Analog Monitor Output Gain
(Fn00D)
You can use this utility function to manually adjust the analog monitor
output gains for the torque reference monitor and motor speed monitor.
You can adjust the torque reference monitor and motor speed monitor
gains individually.
These gains are adjusted at the factory. You normally do not need to use
this utility function.
The setting range for the analog monitor output gains is -128 to 127
(
×
0.4%).
The center value of the gain adjustment range is 100%.
For example, if you set -125, the gain will be 100% - (125
×
0.4%), or
50%. Therefore, the monitor output voltage will be reduced by 1/2. Also,
if you set 125, the gain will be 100% + (125
×
0.4%), or 150%. There-
fore, the monitor output voltage will be increased by a factor of 1.5.
Note: These offsets are not initialized even if you execute the Fn005 (Initialize Parame-
ters) utility function.
Preparations
Always check the following before you adjust gain of the analog monitor
output.
•
The parameters must not be write-prohibited (Fn010 must be set to
0000).
Operating Procedure
Step
Operation
Result
1
Press the
Key to display the
Utility Mode Main Menu, and then
use the
Key or
Key to
select
Fn00D
.
2
Press the
Key.
The Fn00D (Adjust Analog Monitor
Output Gain) execution display will
appear.
Continued on next page.
1 : B B
F U N C T I O N
F n 0 0 C : M o n Z e r o A d j
F n 0 0 D : M o n G a i n A d j
F n 0 0 E : C u r A u t o A d j
F n 0 0 F : C u r M a n u A d j
1 : B B G a i n A D J
C H 2 = - 0 0 0 0 1
U n 0 0 2 =
0
0 0 0 0 0
U n 0 0 0 =
0
0 0 0 0 0
C H 1 = - 0 0 0 0 1